background image

CF

O-12E

  

CFO-20E

DEHUMIDIFIER

USER’S

MANUAL

©

GREE 1999 SY370171001 99

E3CF0029-FM.p65

03-4-30, 17:00

1

Summary of Contents for CFO-12E

Page 1: ...CFO 12E CFO 20E DEHUMIDIFIER USER S MANUAL FM p65 03 4 30 17 00 1 ...

Page 2: ...fer ence if necessary Contents Structure and principle Operation Maintenance Appen dix 1 2 3 4 6 7 9 12 12 13 14 18 Features Specifications How dehumidifying works Structure of dehumidifier Operation steps Operation panel Draining the water Caring for the dehumidifier Storing the dehumidifier Notation for safe operation Removing breakdowns Electric Schematic Diagram ML p65 03 4 30 17 00 1 ...

Page 3: ...p indoor air dry and comfortable Excellent drying laundry function The dehumidifier dries laundry quickly This can prevent laundry and furniture from becoming damp and musty in a rainy season Drainage tank with a large capacity The drainage tank capacity is large to 6 liter this will reduce the times of your discarding water Using refrigerant for protecting environment The dehumidifier uses the no...

Page 4: ...e data on nameplate of the unit The work temperature is in the range 2 to 38 If the room temperature is beyond the range the unit can not operate normally Structure and Principle Power Supply Dehumidifying Capacity Power Consumption Drainage Tank Capacity Weight Dimension height width depth Model CFO 12E CFO 20E 220 230V 50Hz 6 0L automatic stop at about 5 5L 12L day 20L day 220W 400W 12 5kg 14kg ...

Page 5: ...k The dehumidified air is re heated by a heating unit and discharged Steps and are repeated to remove humid ity from the room After the air passes through the re heating unit its temperature will rise a little so that the tempera ture of the room will rise appreciably This is normal phenomenon Cooling unit Re heating unit Moist air Dried air Compressor Drainage tank p65 03 4 30 17 01 3 ...

Page 6: ... 4 30 17 01 4 Structure of dehumidifier Handle Discharge port Float Louver Operation panel Water level gauge Structure and Principle Drainage tank Plastic film NOTE Please take off the plastic film before using ...

Page 7: ... 5 Structure and Principle Continuous drain age port Air filter Air intake port do not obstruct Power supply plug p65 03 4 30 17 01 5 ...

Page 8: ... 1 Plug the power supply plug into the outlet 2 Open the louver by hand 3 Press the power suitch 4 Select operation mode or let it run in the default mode 5 Press the power switch once again to stop operation 6 p65 03 4 30 17 01 8 ...

Page 9: ...light when the unit is plugged in 3 mode indicator lamp When lamp or lamp or lamp is lighted it respectively indicates that operation is in DEHUMI DIFY LAUNDRY or QUIET mode 4 Humidity indicator lamp When 50 lamp 60 lamp or 70 lamp is lighted it respectively indicates that the current setting humidity is 50 60 or 70 CON Continuously dehumidity indicator lamp When CON lamp is lighted it indicates t...

Page 10: ...ange with the operation mode The default is DEHUMIDIFY when the indoor temperature is above 35 the protection device is actuated the unit only can operate in LAUNDRY mode and pressing switch is ineffective 7 switch Press the switch to set the humidity of the room which can be set in order of 50 60 70 and continuous the defanlt is continuous When the relative humidity of the room is lower than your...

Page 11: ...uring pads chemically treated dustcloths gasoline benzene thinner or other solvents to clean it as these can scratch and damage the tank and cause water to leak Take hold of the handle and then remove the tank discard the water Drainage steps Notation for drainage When place back the drainage tank press the tank firmly into place with both hands If the tank is not positioned properly the Ò Tank Fu...

Page 12: ...f 15mm through the continuous drainage port and press it firmly into the drainage port in the main unit make sure water does not leak The level height of drain piping should al ways be not higher than the one of the drainage port also drain piping should always be not plugged up so the con densed water can be drained out successfully 3 Return the drainage tank to its original position Check the ho...

Page 13: ...stop working and discard the water before move the dehumidifier Tilt it within range of 30 degrees Note Make sure at lease some place is provided around it when the unit is operating Operation p65 03 4 30 17 01 11 ...

Page 14: ...er left in the drainage tank and wipe away any remaining drops with a cloth 3 Clean the air filter Clean the air filter The air filter should be cleaned approximately once two week First Remove the air filter then run a vacuum cleaner lightly over the surface of the air filter to remove dirt If the air filter is very dirty wash it with warm water and a neutral cleaning solvent and dry it thoroughl...

Page 15: ...evices or near inflammable and dangerous article 5 Never put your fingers or objects into the intake or discharge ports 6 Do not sit or stand on the unit 7 Discard water that has collected in the tank timely 8 Do not run the dehumidifier in an closed area such as inside closets or fire can take place 9 Do not use the unit for special purposes such as edible items objects of art or scientific mater...

Page 16: ...d then reposition the tank The protection device is actuated and the unit can not be started in case operation is under the bad environment in that case please donotusethedehumidifier Is the temperature of the room above 38 or below 2 If a condition listed below occurs please check the following items to help you to save your time and cost Condition Cause What to do Maintenance Removing breakdowns...

Page 17: ...s instructed un der Caring for the dehumidifier Use the unit in a stable sturdy location Prompt Put a cushion under the unit and help to reduce operation noise Operation is noisy Has the unit been poorly installed so it is tilted or unsteady Is the air filter clogged Clean the air filter as instructed un der Caring for the dehumidifier After the above condition has occurred and corresponding step ...

Page 18: ...h as a kerosene stove which emits steam Very little dehumidifying takes place or none takes place This happens if the temperature and or humidity of the room is low When the unit is first used the dis charged air smells musty Because the temperature of the head exchanger rises abruptly an unusual or musty odor may be produced for a moment The following symptoms do not indicate a breakdown Symptom ...

Page 19: ... press mode switch This is water left from the dehumidifying test conducted at the factory it does not indicate a problem The fan is running and the compressor does not work If the unit is started within 3 minutes after the unit stops the protection device is actuated so that the compressor is started automatically after a delay of 3 minutes or the automatic defrosting operation is activated and t...

Page 20: ... 18 APPENDIX Electric Schematic Diagram p65 03 4 30 17 01 18 ...

Reviews: