background image

TRT-BA-B6E-TC2017-60-005-EN

B 6 E

EN

OPERATING MANUAL

HUMIDIFIER

Summary of Contents for B6E

Page 1: ...TRT BA B6E TC2017 60 005 EN B 6 E EN OPERATING MANUAL HUMIDIFIER ...

Page 2: ...he device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and...

Page 3: ...age Do not drink the water Health hazard Note that high humidity levels may enhance the growth of biological organisms in the environment Make sure that objects in the surroundings of the device do not become wet or damp If moisture is present the output must be reduced If the output cannot be reduced the device must only be operated in intervals Absorbent materials such as carpeting curtains shee...

Page 4: ...he hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Caution If the device is knocked over water will leak from the lower part Disconnect the device from the mains to prevent damage to the device caused by dry running Note Do not operate the device without an air filter inserted into the air inlet Without the air filter the...

Page 5: ...f you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Before transporting the device observe the following Switch off the device Hold onto the mains plug while pulling the power cable out of the mains socket Empty the water tank Do not use the power cable to drag the device Check whether the upper part ...

Page 6: ...e sound condition contact the customer service Only put up the device in an upright stable position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are unrolled completely Make sure that there are no moisture sensitive objects located...

Page 7: ...ory 7 into the water tank 1 7 Screw the tank lid 13 firmly back onto the water tank 2 6 13 8 Refit the water tank 2 into the device ð When doing so make sure that the water tank is correctly inserted in the guide ð Please note that after inserting the water tank the water immediately starts to run into the bottom of the device 9 Refit the mist nozzle 1 onto the water tank 2 ...

Page 8: ...move the scented oil tank 9 from the device 9 2 Put 2 to 3 drops of scented oil onto the sponge in the scented oil tank 9 3 Push the scented oil tank 9 back into the device Inserting the air filter Note Do not operate the device without an air filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result...

Page 9: ...d 21 iItelligent indication Illuminated when automatic mode is activated 22 Sleep indication Illuminated when night mode is activated Operating elements 23 24 25 26 28 27 No Designation Description 23 Mode button Setting the operating mode standard manual humidification intelligent automatic mode sleep night mode 24 Humidity button Setting the relative room humidity 25 Timer button Switching the t...

Page 10: ...cation appears on the display Manual humidification The device always starts in this operating mode The current room humidity and nebulizer intensity are shown on the display The desired relative room humidity can be adjusted at any time in this operating mode The setting options are 40 50 60 70 80 or OL continuous humidification regardless of the room humidity The nebulizer intensity can be adjus...

Page 11: ...ting equals the desired number of hours ð The current room humidity is displayed again ð The device switches off after the set period of time Note regarding automatic switch off Pressing the On Off button 26 deactivates the automatic switch off function The timer stops when the lacking water indication 17 lights up The timer continues to run as soon as the water tank is full again Switching ioniza...

Page 12: ... with clear water and if required carefully clean the filter at the filter cartridge Check the valve in the water tank lid The valve must be able to move freely If necessary clean the water tank Water is leaking Check whether the device is set up in a stable and upright position Check the water level in the lower part of the device The water level might be too high and water is discharged via the ...

Page 13: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary ...

Page 14: ...on of germs by means of silver ions Due to the special antimicrobial surface the silver ions are emitted to the immediate proximity of bacteria and germs This way microbial growth can be effectively prevented at the same time the water remains pure and uncontaminated The dosage of the SecoSan Stick is carried out automatically The water tank should be cleaned every 3 days if actively used Use hous...

Page 15: ...ater immediately starts to run into the bottom of the device 16 Refit the mist nozzle 1 onto the water tank 2 Cleaning the nebulizer membrane Depending on the hardness of the drinking water used deposits may form on the nebulizer membrane over time These could affect the nebulizer performance Therefore the nebulizer membrane should be cleaned on a regular basis To do so please proceed as follows 1...

Page 16: ...4 Provide a vessel containing saturated saline solution 5 Place the filter cartridge into the vessel containing saline solution Make sure that the filter cartridge is completely covered by the saline solution 6 Leave the filter cartridge in the saline solution for 24 h 7 Take the filter cartridge out of the saline solution after 24 h 8 Rinse the filter cartridge with clear water 9 Screw the filter...

Page 17: ...aged The corners and edges of the air filter must not be deformed or rounded Before reinserting the air filter make sure that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device 2 Rinse the filter with warm water 3 Allow the filter to dry completely D...

Page 18: ...ulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website https de trotec com shop The separate collec...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: