Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Cleaning the water tank
Info
Use the SecoSan
®
Stick by Trotec to provide protection
from germs in the water. The SecoSan
®
Stick prevents
the reproduction of germs by means of silver ions. Due
to the special, antimicrobial surface, the silver ions are
emitted to the immediate proximity of bacteria and
germs. This way, microbial growth can be effectively
prevented – at the same time, the water remains pure
and uncontaminated. The dosage of the SecoSan
®
Stick is carried out automatically.
The water tank should be cleaned every 3 days if actively used.
Use household vinegar as cleaning/descaling agent. Observe the
manufacturer's specifications and hazard warnings of the
descaling agent. Before a longer period of non-use or storage
the water tank should be drained.
1. Remove the mist nozzle (1) from the water tank.
2. Remove the water tank (2) from the device by lifting the
water tank at the transport handle (4).
Note that there may still be residual water left in the lower
part (3) if the device was used beforehand.
3
2
1
4
3. Turn the water tank over.
4. Unscrew the fuel tank cap (13).
13
6
5. Drain the residual water from the water tank.
6. Take the SecoSan
®
Stick out of the water tank (1).
7. Thoroughly rinse the water tank with household vinegar
(descaling agent).
8. Thoroughly rinse the water tank and the SecoSan
®
Stick
with clear water.
9. Allow the water tank to dry.