Vigor2926 Series User’s Guide
728
Any: It means any port number can be used as destination port.
-G [default/specific]
Specify the gateway mode.
-L [default/specific]
Specify the failover gateway mode.
-s [value]
Indicate the source IP start.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g, 192.168.1.0)
-S [value]
Indicate the source IP end.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g,
192.168.1.100)
-d [value]
Indicate the destination IP start.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g, 192.168.2.0)
-D [value]
Indicate the destination IP end.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g,
192.168.2.100)
-p [value]
Indicate the destination port start.
Value: Type a number (1 ~ 65535) as the port start (e.g., 1000).
-P [value]
Indicate the destination port end.
Value: Type a number (1 ~ 65535) as the port end (e.g., 2000).
-y [value]
Indicate the priority of the policy route profile.
Value: Type a number (0 ~ 250). The default value is “150”.
-I [value]
Indicate the interface specified for the policy route profile.
Value: Available interfaces include,
LAN1 ~ LAN8, IP_Routed_Subnet,
DMZ_Subnet,
WAN1 ~ WAN5,
VPN_PROFILE_1 ~ VPN_PROFILE_100,
WAN_1_IP_ALIAS_1 ~ WAN_4_IP_ALIAS_8
-g [value]
Indicate the gateway IP address.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g, 192.168.3.1)
-l [value]
Indicate the failover IP address.
Value: The type format shall be “xxx.xxx.xxx.xxx”. (e.g, 192.168.4.1)
-t [value]
It means “protocol”.
Value: Available settings include “TCP”, “UDP”, “TCP/UDP”, “ICMP”
and “Any”.
-n [0/1]
Indicates the function of “Force NAT”.
0: Disable the function.
1: Enable the function.
-a [0/1]
Indicates to enable the function of failover.
0: Disable the function.
1: Enable the function.
-f [value]
It means to specify the interface for failover.
Value: Avaialbe interfaces include,
NO_FAILOVER,
Default_WAN,
Policy1 ~ Policy60
LAN1 ~ LAN8
IP_Routed_Subnet,
DMZ_Subnet,
WAN1 ~ WAN5,
VPN_PROFILE_1 ~ VPN_PROFILE_100,
WAN_1_IP_ALIAS_1 ~ WAN_4_IP_ALIAS_8
-b [value]
It means “failback”.
Value: Available settings include,
0: Disable the function of “failback”.
Summary of Contents for Vigor2926
Page 1: ...i ...
Page 4: ...Vigor2926 Series User s Guide iv ...
Page 14: ......
Page 16: ......
Page 66: ...Vigor2926 Series User s Guide 50 This page is left blank ...
Page 112: ...Vigor2926 Series User s Guide 96 ...
Page 149: ...Vigor2926 Series User s Guide 133 ...
Page 154: ...Vigor2926 Series User s Guide 138 ...
Page 204: ...Vigor2926 Series User s Guide 188 ...
Page 310: ...Vigor2926 Series User s Guide 294 This page is left blank ...
Page 410: ...Vigor2926 Series User s Guide 394 The items categorized under OTHERS ...
Page 436: ...Vigor2926 Series User s Guide 420 ...
Page 450: ...Vigor2926 Series User s Guide 434 ...
Page 465: ...Vigor2926 Series User s Guide 449 ...
Page 470: ...Vigor2926 Series User s Guide 454 ...
Page 544: ...Vigor2926 Series User s Guide 528 ...
Page 547: ...Vigor2926 Series User s Guide 531 ...
Page 588: ...Vigor2926 Series User s Guide 572 ...
Page 610: ...Vigor2926 Series User s Guide 594 This page is left blank ...
Page 688: ...Vigor2926 Series User s Guide 672 ...
Page 696: ...Vigor2926 Series User s Guide 680 ...
Page 700: ...Vigor2926 Series User s Guide 684 ...
Page 702: ...Vigor2926 Series User s Guide 686 This page is left blank ...
Page 706: ...Vigor2926 Series User s Guide 690 ...