25
Technical data
Extract, see the Technical Manual for details.
Ambient conditions:
During operation
–40 to +77 °C (–40 to +170 °F), 700 to 1300 hPa, 0 to 100 % r.h.
During storage
–40 to +85 °C (–40 to +180 °F), 700 to 1300 hPa, 0 to 100 % r.h. non-condensing
Protection class
IP 66 and IP 67, Nema 4X
Power consumption
5,6 W (typical), <7 W (maximum)
Warm-up time (after switch-on)
1 minute
Electrical connection
Cable diameter 7 to 12 mm, conductor cross-section max. 2.5 mm
2
or 2 x 1 mm
2
CE mark
Device and safety systems for intended use in potentially explosive atmospheres (Directive 94/9/EC)
Dimensions
approx. 160 mm x Ø89 mm
Weight
approx. 2.2 kg (without accessories)
Approvals:
ATEX
Type: IDS 01xx
Dräger Safety • 23560 Lübeck • Germany
II 2G Ex d IIC T6/T4 Gb – DEMKO 07 ATEX 0654417X
II 2D Ex tb IIIC T80 °C/T130 °C Db IP65 – PTB 07 ATEX 1016
–40 °C
Ta
+40 °C/+80 °C
Measurement functions for explosion protection (only 4-20 mA signal output) - BVS 08 ATEX G 001 X
1)
Type 334: acetone, allyl chloride, benzene, i-butane, n-butane, 1.2-dichlorethane, dichlormethane, 1.2-dichlorpropane, 1.3-
dichlorpropene, epichlorhydrin, ethanol, ethyl acetate, ethylene, ethylene oxide, n-hexane, methane, methanol,
1-methoxy-2-propanol, methyl chloride, methyl-i-butyl ketone, methyl ethyl ketone, n-nonane, n-octane, n-
pentane, propane, i-propanol, propylene, propylene oxide, styrene, toluene, o-xylene - all in the measuring range
0 to 100 %LEL. Methane in the measuring range from 0 to 100 vol. %.
Type 340: acetone, allyl chloride, i-butane, n-butane, cyclohexane, 1.2-dichlorethane, dichlormethane, 1.2-dichlorpropane,
1.3-dichlorpropene, epichlorhydrin, ethanol, ethyl acetate, ethylene oxide, n-hexane, methane, methanol,
1-methoxy-2-propanol, methyl chloride, methyl-i-butyl ketone, methyl ethyl ketone, n-nonane, n-octane,
n-pentane, propane, i-propanol, propylene, propylene oxide, toluene, o-xylene - all in the measuring range 0 to
100-%LEL.
Year of manufacture (by serial number)
2)
IECEx
Type: IDS 01xx
Dräger Safety • 23560 Lübeck • Germany
Ex d IIC T6/T4 Gb – IECEx UL 07.0009X
Ex tb IIIC T80 °C/T130 °C Db IP65 – IECEx PTB 07.0016
–40 °C
Ta
+40 °C/+80 °C
Year of manufacture (by serial number)
2)
UL (Classified)
Type: IDS 010x
Class I, Div. 1, Groups A, B, C, D / Class II, Div. 1, Groups E, F, G / Class I, Zone 1, Group IIC
T code T6/T4, –40 °C
Ta
+40 °C/+80 °C
9 to 30 V DC, 9 W - Type 4x
CSA (C-US)
Type: IDS 010x
Class I, Div. 1, Groups B, C, D / Class II, Div. 1, Groups E, F, G
T-Code T6/T4, –40 °C
Ta
+40 °C/+80 °C
C22.2 no. 152
9 to 30 V DC, 9 W - Type 4x
1) The considered substance must be selected as measuring gas. The calibration must be carried out with the selected substance or alternatively with approx. 50 %LEL propane.
2) The year of manufacture is read from the 3rd letter in the serial number on the type plate. Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.
Example: Serial number ARYH-0054, the 3rd letter is Y, so the year of manufacture is 2007.
0158
Summary of Contents for PIR 7000
Page 238: ...238 1 2 Dr ger PolySoft HART Dr ger 4 20 1 2 1 2 1 2 1 2 0 4 20 Dr ger Dr ger...
Page 357: ...357 1 2 15 30 S 5 Dr ger RAB 7000 Dr ger PolySoft HART 40 60 Dr ger PolySoft 0 S S 0 2...
Page 400: ...400...
Page 401: ...401...
Page 402: ...402...
Page 403: ...403...
Page 404: ...404...
Page 405: ...405...
Page 406: ...406...
Page 407: ...407...
Page 408: ...408...
Page 409: ...409...
Page 410: ...410...
Page 413: ...413...
Page 414: ...414...
Page 415: ...415...
Page 416: ...416...
Page 417: ...417...
Page 419: ......