53 / 96
A B C D
E
F
G H
I
J
K
L M Possible cause
Remedy
4)
-
-
-
✘
✘
-
-
-
✘
-
✘
-
✘ Pump / piping not completely vented
and/or primed.
Vent and prime.
-
-
-
✘
✘
✘
-
-
✘
✘
✘
-
✘ Check valve in bypass line defective
Replace.
-
-
-
-
-
✘
-
-
-
-
-
-
-
Insufficient inflow
Restore normal inflow. Connect
accumulator.
-
-
-
-
-
✘
-
-
✘
✘
-
-
✘ Pump runs sluggishly.
Have pump repaired by a specialist.
-
-
-
-
-
-
-
✘
-
-
-
-
-
Defective mechanical seal
Replace.
-
-
✘
-
-
-
-
-
✘
-
-
-
✘ Incorrect pre-charge pressure of
accumulator
Set correct pre-charge pressure.
Replace membrane.
✘
-
✘
✘
-
-
-
-
-
✘
✘
-
-
Inlet-side pressure switch defective or
set incorrectly.
Check the value set at the pressure
switch; adjust if required.
-
-
-
-
-
-
-
-
✘
-
✘
✘
✘ Defective time relay or time set
incorrectly.
Check time relay. Correct minimum
operating time if required.
-
-
-
-
-
-
-
-
-
-
-
✘
-
System leaking.
Restore system integrity.
-
-
✘
-
-
✘
✘
-
-
-
✘
✘
-
Discharge-side pressure switch
defective or set incorrectly.
Check the value set at the pressure
switch; adjust if required.
✘
-
-
-
-
-
-
-
-
✘
-
-
-
Intermittent voltage fluctuations
Press reset/fault acknowledgement
key.
-
-
-
✘
-
-
-
-
✘
✘
-
-
✘ Defective check valve
Check and replace if necessary.
-
-
-
✘
✘
✘
-
-
✘
-
✘
-
-
Pump running in the wrong direction
of rotation.
Interchange two of the phases of the
power supply.
-
-
-
✘
-
✘
-
-
-
-
✘
✘
-
Inlet pressure lower than specified in
the purchase order
Connect suction-side inlet tank.
Contact the manufacturer.
-
✘
-
-
-
✘
-
-
-
✘
✘
-
-
Water extraction higher than specified
in the purchase order
Contact the manufacturer.