![Dover Anthony Complete 101 Series Installation Manual Download Page 124](http://html1.mh-extra.com/html/dover/anthony-complete-101-series/anthony-complete-101-series_installation-manual_2524816124.webp)
Complete 101 Series Installation Manual
99-25517-I001 July 2022 Rev. B
123 |
P a g e w w w . a n t h o n y i n t l . c o m
Troubleshooting
•
When the unit is operating normally, the LED of the sensor will display the status of the heater.
•
When the heater is off, the LED will blink very dimly to show that the unit is operating, but the heater is off.
•
When the heater is on, the LED will be illuminated constantly.
•
Sensor Disconnect - If at any time during normal operation a sensor is disconnected, via a cut wire or fully disconnected the sensor, the
LED will blink quickly, and the heater will be on to ensure the glass does not sweat.
Replacement Part Numbers
The following table is a list of replacement part numbers for your Anthony Energy Controller.
Replacement Part Number
Description
Quantity
60-22715-0002
AEC Energy Controller Assembly
1 per Frame Section
40-25072-1005
Screws for AEC Energy Controller
2 per Frame Section
40-12665-3003
Screws to install Humidity Sensor
2 per Frame Section
40-12665-3003
Screw to Install Temperature Sensor
1 per Frame Section
20-24817-0001
20-24817-0002
Humidity Sensor Cover
1 each per Frame Section
Replacement Instructions
The following instructions will guide you on how to replace an Anthony Energy Controller.
1.
Locate the Mullion with LED Light Switch and remove the contact plate by disengaging the zipper strips.
2.
Locate the Energy Controller and unscrew the Controller.
3.
Locate the Temperature sensor located on the Frame sill towards the left side. Remove the contact plate and unscrew the sensor
4.
Also, unscrew the Humidity Sensor from the Frame header.
5.
Replace the Energy Controller and screw the Temperature Sensor and Humidity Sensor.
6.
Check if the newly replaced Energy controller is working. (refer to the troubleshooting instructions)
7.
Put back the Mullion and Sill contact plates by engaging zipper strips. (If needed use new Zipper Strips).