![Dover Anthony Complete 101 Series Installation Manual Download Page 123](http://html1.mh-extra.com/html/dover/anthony-complete-101-series/anthony-complete-101-series_installation-manual_2524816123.webp)
Complete 101 Series Installation Manual
99-25517-I001 July 2022 Rev. B
122 |
P a g e w w w . a n t h o n y i n t l . c o m
24-Hour Heat Mode
This mode is used to turn 24-hour constant heat on Frame/Door System, this mode will keep the heat on for a continuous 24-hour period and
then revert to the previous setting. When the unit is in a 24-hour heat mode, the LED will blink slowly with an interval of 1 second to indicate
that the heater is on for the remainder of the 24-hour heat mode. To set hold down the button for longer than 10 seconds but less than 20
seconds, the 24-hour heat mode is displayed by flashing the LED slowly. If the button is released during this time, the unit will either enter
the 24-hour heat mode if it is not in it already or leave it if it is already in this mode.
Offset Setting Options
When the sensor button is held for longer than 20 seconds, the LED will flash once, twice, three times, or four times in Five Second Intervals.
The blink represents the Temperature offset point in addition to Cut off Temperature (Dew Point Tempe 10ºF).
•
1 Blink ( 1/2 Second Blink. No Blink for 4 1/2 Seconds)
•
No offset (The overall cut off Temperature is (Dew point Tempe 10ºF)
•
2 Blinks (Blinks for 1 Second. No Blinks for 4 Seconds)
•
3°F offset (The overall cut off Temperature is (Dew point Tempe 13ºF)
•
3 Blinks (Blinks for 1 1/2 Seconds. No Blinks for 3 1/2 Seconds)
•
9°F offset (The overall cut off Temperature is (Dew point Tempe 19ºF)
•
4 Blinks (Blinks for 2 Seconds. No Blinks for 3 Seconds)
•
18°F offset (The overall cut off Temperature is (Dew point Tempe 28ºF)
Release the sensor button when the desired dewpoint offset flash is displayed via the LED. The technician then can check the setpoint by
entering the Offset Status Indicator Mode, as previously described.