Page 1: ...0 P a g e LA GARD SERIES 700 System User Guide For Models 701 705 ...

Page 2: ...ob 10 2 2 9 Power Considerations 10 2 3 Getting Started 11 3 How to Use the System 11 3 1 Keypad Model Definitions 11 3 2 Keypad Layout Usage and Settings 14 3 2 1 Keypad Layout General Usage 14 3 2 2 Using a Display Keypad Menu Settings 14 3 2 3 Using a Non Display Keypad Commands 16 3 3 System Functions 16 3 3 1 System Info Display Only 17 3 3 2 Backlight Mode 18 3 3 2 1 Backlight Mode Display K...

Page 3: ...rs 23 3 4 1 Lock User Types 23 3 4 1 1 Master 23 3 4 1 2 Manager 24 3 4 1 3 Standard Users 24 3 4 2 User Privileges 24 3 4 2 1 User Privileges Access Lock 24 3 4 2 2 User Privileges Audit Lock 25 3 4 2 3 User Privileges Time Delay Override with Combination 25 3 4 2 4 User Privileges Time Delay Override with Fob Credential 25 3 4 3 Assigning User IDs and Privileges 28 3 4 3 1 Add User Display Keypa...

Page 4: ...itical Low Battery Warning 38 3 10 2 1 Critical Low Battery Warning Display Keypad 38 3 10 2 2 Critical Low Battery Warning Non Display Keypad 38 3 10 3 Replacing Batteries in Critical Low Battery State 38 3 11 View Audits Display Keypad Only 38 3 12 Wrong Try Penalty 39 3 13 Locks 39 3 13 1 Physical Installation of a Lock 39 3 13 2 Uninstall Electronically Un pair a Lock 39 3 13 2 1 Uninstall a L...

Page 5: ... During Time Delay Using Override with FOB 45 3 15 Auto Open 47 3 15 1 Aspects of Auto Open 47 3 15 1 1 Auto Open Interactions with other features 48 3 15 1 2 Auto Open Feedback 48 3 15 1 3 Auto Open Feedback with battery level low or critical 49 3 15 2 Configure Auto Open Display Keypad 49 3 16 Assign Time Lock Schedules 50 704 705 Models Only 50 3 17 Time Date Rules in LA GARD 700 Series Locks 5...

Page 6: ...uide 7040 1121 Rev E 10 22 5 Appendix C LA GARD 700 Series Simple Set Up 701 with 1 Manager 1 Standard User 6 Digit Combination 64 Appendix D LA GARD 700 Series Simple Set Up 702 with 1 Manager 1 Standard User 6 Digit Combination 68 ...

Page 7: ...rence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...

Page 8: ...if Cet appareil numérique de la classe B respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada 1 2 Electrical Precautions Ensure alkaline batteries where applicable are new and in good condition leaking batteries can cause damage to components and can also cause serious bodily harm Do not apply power where applicable before completing all steps of the installation doing s...

Page 9: ...e The following diagrams Figures 1 and 2 show completed system layouts for both single and multi lock systems Please note that your system may not include all components shown Figure 1 Single Lock System Battery box alarm box or AC adaptor LA GARD Prgm Cable LA GARD Keypad Swingbolt Safe Lock Figure 2 Multi Lock System Battery box alarm box or AC adaptor LA GARD Prgm Cable LA GARD Keypad Lock 1 Mu...

Page 10: ... Guide Document 7033 0322 for more information 2 2 2 Multiplexer The Multiplexer is used in multi lock systems and allows multiple safe locks to connect with the Keypad Refer to the Multiplexer Installation Guide Document 7038 0521 for more information The Multiplexer is not UL evaluated Item Order 704033 Multiplexer 2 2 3 Safe Lock The safe lock is either a dead bolt a spring bolt or a swing bolt...

Page 11: ...ombination to open a lock The fob cannot be used as sole means to operate and open the lock Item Order 890165 FOB Bluetooth Enabled Credential 2 2 9 Power Considerations The system common power across all components As long as 9V DC power is supplied to the system the system will work as intended It is unnecessary to apply multiple sources of power to some or all components Some considerations to ...

Page 12: ... Read Section 3 5 Install Electronically Pair a Lock and Keypad for instructions on performing this step b Add Users Read Section 3 4 3 Assigning User IDs and Privileges for instructions on adding all non Master users c Change Master User Combination Read Section 3 7 Change Combination for instructions in changing the Combination for the Master User 3 Customize the System a For Keypad Models 702 7...

Page 13: ... 5 Dual User Mode No Yes Yes Yes Yes Reset Function Yes Yes Yes Yes Yes Time Delay No 0 99 Min 0 99 Min 0 99 Min 0 99 Min Confirmation Window No 1 60 Min 1 60 Min 1 60 Min 1 60 Min Time Delay Override TDO No Yes Yes Yes Yes TDO with BLE Key fob No No No No Yes Programmable at Keypad Yes 702D Only Yes Yes Yes Programmable by PC No Yes Yes Yes Yes Audit Events No 500 500 2000 6000 View Audit Trail N...

Page 14: ... Yes Bolt Switch Option No Yes Yes Yes Yes Wrong Try Penalty Yes Yes Yes Yes Yes Battery Power 2 x 9V 2 x 9V 2 x 9V 2 x 9V 2 x 9V Low Profile Option No Yes Yes Yes No AC Power Option Yes Yes Yes Yes Yes VdS 2396 Class 2 Yes Yes Yes Yes No UL 2058 UL Type 1 Yes Yes Yes Yes Yes EN1300 Level B Yes Yes Yes Yes No SBSC 3880 2015 Yes Yes Yes Yes No CNPP q2p Level B E Yes Yes Yes Yes No Time Lock Schedul...

Page 15: ...p and Down Arrows Navigate through options with these for Display Keypads Return Key Confirms a selection or complete a command sequence 3 2 2 Using a Display Keypad Menu Settings To enter the Main Menu press any non numeric button followed by your user credentials Below is a table outlining each Menu Setting and sub setting within the Keypad display interface Note that the menu available changes ...

Page 16: ...rs port Lock and Open Count Backlight Toggle the Backlight On and Off Buzzer Toggle the Buzzer sound On and Off TD Cnt Mode Set counting period to count up down or not show time in the periods Combination Combo Length Determines the length of a combination Force Change Determines whether or not new Users will have to change their combination after initial login choose Yes No User Mode Choose betwe...

Page 17: ...nd change various aspects such as Combination length Buzzer and Backlight amongst other options Below is a table that outlines Buzzer LED and Screen Messages in response to certain events Table 4 Buzzer LED and Screen Message s Event Buzzer LED Screen Message s Display Only System wakeup Short high beep Short green flash N A Set Combo Length 11 Open PC Link 30 Delete User 56 Set User Mode 12 Reins...

Page 18: ...flashes Low Battery Critical Low Battery 3 long low beeps 3 long red flashes Critical Low Battery Master Reset 3 short high beeps 3 short green flashes Reset Success Power On No lock connected 5 medium to low beeps 5 medium red flashes No Lock Found Turn Power Off and Connect Power On Bad configuration 5 medium to low beeps 5 medium red flashes Bad Config Power On Wake Up Lock Connected but Not In...

Page 19: ...f applicable Note This function is not available on the 701 series Keypad 3 3 2 1 Backlight Mode Display Keypad Follow these steps to toggle the Backlight Mode On and Off on a Display Keypad 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select System 3 Select Backlight from the sub menu 4 Select between On and Off to Enable Disable Backlight Mode 5 Success Mode...

Page 20: ...ll then need to change their combination again in order to use the system Since the Master User is the only one whose combination is unaffected by change in Combination length the Master must reset other users combinations Once a Manager s Combination is reset and then changed again the Manager can reset other users combinations 3 3 4 1 Combo Length Display Keypad Follow these steps to change the ...

Page 21: ...key 2 The Keypad will beep and flash a green LED three times to indicate the setting has been successfully changed 3 3 6 User Mode The User Mode is a system setting that determines how many Users and what class of user can gain access to the Keypad and applies to all locks connected to the System The User Mode can only be set by the Master Table 5 User Modes Mode Lock Access Notes Single 1 Access ...

Page 22: ... steps to change the Credential Mode 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select System 3 From the sub menu select Cred Mode 4 From the list provided select between Single Dual and Dual Mgr 5 Success Mode updated will appear on screen and the Keypad will beep three times and flash a green LED once complete 3 3 8 Duress Mode Silent Alarm Note Duress Mod...

Page 23: ...lti lock system Lock 1 monitors the state of this signal and depending on how it is configured it will perform one of the following functions when this signal is asserted Ignored Input Signal will have no effect on how the system operates Remote Disabled Lockout When an open lock request is received for any lock all requests to open will be blocked regardless of which target lock the user is attem...

Page 24: ...verride 3 Remote Dual User Override return key 2 The Keypad will beep three times and flash a green LED once complete 3 4 Users 3 4 1 Lock User Types There are three types of users each with different capabilities The sub sections outlined below cover each Lock User Type and their respective functions 3 4 1 1 Master There will always be 1 Master User per safe lock Combination length is always 8 di...

Page 25: ... is applied to a safe lock Can bypass Dual User mode if not included in Dual User Requirement Can bypass Dual Credential mode if not included in Dual Credential Requirement 3 4 1 3 Standard Users Note The Combination Length Requirement is a system setting and will therefore be the same for all Managers and Users The combination is in the format of 2 ID digits plus 6 to 9 combination digits The for...

Page 26: ...hows the permitted mix of capabilities a user may perform The configuration software and lock firmware shall enforce this capability mix The numbers in the table represent the states of each user privilege 1 enabled 0 disabled Table 7 User Capabilities TDO w fob TDO w Combo Audits Access User Capabilities 1 0 0 0 Can Override Time Delay by presenting a fob during an open sequence that was initiate...

Page 27: ...liday Schedules on Keypad Yes default Yes default Set Time Format Yes default Set Date Format Yes default Daylight Saving Time DST Enable Disable Yes default Yes default Set Date Time Yes default Yes default View Audits on Keypad Yes default Yes default Requires Audit Privilege Retrieve Audits to PC Yes default Yes default Requires Audit Privilege Activate PC Link Yes default Yes default Requires ...

Page 28: ...move Time Delay Override Privilege for a Manager User Yes default Yes default Re enroll key fob Yes default Yes default Set Time Delay Delay Period Open Period Time per lock Yes default Yes default Change Manager Combination Yes default Yes default Open Lock Yes default Yes default Change User Combination Yes default Yes default Requires Access Audit or TDO with TDO Fob Privilege Time Delay Delay ...

Page 29: ...ay Keypads Non Display Keypads or using a PC link to the LA GARD Software The following section details the Keypad instructions for adding users Note The forced change on first use rule applies to all non Master users 3 4 3 1 Add User Display Keypad Follow these steps to add a User on a Display Keypad 1 Enter an Authorized User ID and Combination 2 Navigate through the Main Menu and select Users 3...

Page 30: ...n LED once complete 3 4 3 2 Add User Non Display Keypad Follow these steps to add a User on a non Display Keypad 1 Using the Keypad perform the following sequence of keystrokes a Input the pound key then the number 50 b Input the Authorized User ID and Combination c Input the New User ID and Combination d Input the User Type 2 Standard 4 Manager e Input the User Lock Privileges 1 Open Lock 2 Audit...

Page 31: ...ect User Type b Select between Standard User and Manager 6 Navigate through the options and select Update User Success appears on screen The Keypad will beep three times and flash a green LED once complete 3 4 4 2 Edit User Non Display Keypad For keypads without a display do one of the following Enable Disable User Temporarily suspends user access to the system For example if a user is on vacation...

Page 32: ...5 Confirm delete appears on screen Press the return key on the Keypad to confirm deletion 6 User deleted appears on screen The Keypad will beep three times and flash a green LED once complete 3 4 5 2 Delete User Non Display Keypad Follow these steps to delete a User on a non Display Keypad 1 Using the Keypad input 56 Authorized User ID and Combination User ID to be Deleted return key 2 The Keypad ...

Page 33: ...red LED is illuminated the system is awake and the 1 key will open the lock or the keypad is ready process set up commands 2 With the system awake enter the following to change the Master Combination i The pound sign followed by the number 52 ii Enter the default Master ID and Master Combination 00 12345678 iii Enter the Master ID and a new unique Master Combination 00 _ _ _ _ _ _ _ _ iv Confirm t...

Page 34: ... a safe lock with a Preconfigured User to a non OLED Display Keypad 1 Push any key to wake up the system in factory mode it will beep and display the red function indicator light for 10 seconds The system is awake and the 1 key will open the lock or the keypad is ready to process set up commands 2 a Press 1 to test the opening of the lock OR b With the system awake do the following i Enter the pou...

Page 35: ...sult Section 3 14 Time Delay in this document for more information 3 6 4 Open a Lock Non Display Keypad Follow these steps to open a Safe Lock on a non Display Keypad 1 Enter the User ID and Combination 2 The lock s latch will open After 3 seconds the lock s latch will close If Time Delay is in effect the lock will not automatically open Consult Section 3 14 Time Delay in this document for more in...

Page 36: ...m the Keypad display Main Menu select Change combo 3 New Combo appears on screen Input a new combination with the number pad Note The new Combination must be different from the old Combination The User is advised to use a non trivial combination 4 Confirm appears on screen Input the same combination from the previous step to confirm Success will appear on screen The Keypad will beep three times wi...

Page 37: ...placing a 703B with a 703 model AND the system is configured to require Dual Credential then any user required to present Dual Credentials will not be able to perform any actions associated with their role Since the Master user is always Single Credential the Master user can perform the actions associated with his role Under these conditions the Master user will be able to change the Credential Mo...

Page 38: ... to the LA GARD help menu and to section 3 17 Time Date Rules in LA GARD 700 Series Locks 3 10 Battery Levels On a Keypad with a display screen a battery level indicator is located at the bottom right of the screen The battery level indicator shows 5 levels of battery power Additionally on a Display Keypad indications will be made when the battery level reaches low level and again when it reaches ...

Page 39: ...flashes followed by 3 low LED beeps and 3 red LED flashes 3 10 3 Replacing Batteries in Critical Low Battery State When in Critical Low battery state and the batteries are within the secure container the system must do a restart when a battery or batteries is applied to the Keypad The restart can be forced by pressing the key when the new battery is applied to the Keypad The safe should be opened ...

Page 40: ...e Keypad will respond to any key with 2 short low beeps and 2 red flashes When the Wrong Try Penalty is over the LED will flash green twice and the keypad will produce 2 high beeps For Non Display Keypads 2 short low beeps and 2 short red flashes will repeat every 10 seconds to signify the penalty is in effect During the penalty the Keypad will respond to any key press with a short low beep When t...

Page 41: ...can be done one of two ways 1 Master Reset via the Keypad both Display and Non Display versions 2 Mechanical Reset via the Reset Box Item Order 704065 When a lock is reset The Master Combination is reverted to the default 1 2 3 4 5 6 7 8 All Managers and Standard Users are deleted All System and lock settings will be reset to their default All locks will be uninstalled and unpaired from any Keypad...

Page 42: ...7039 0521 for more information The Mechanical Reset is not UL evaluated It is important after the reset operation that the Reset Box is disconnected from the operational lock If the safe door is closed with the reset box attached the lock will no longer open 3 14 Time Delay During a Time Delay the safe lock cannot be opened until the delay period expires The Time Delay period ranges from 00 Disabl...

Page 43: ... the keypad to input a new Confirm Window time between 01 and 60 minutes Note For a multi lock setup repeat Steps 5a through 5d for each safe lock e Success TD Updated appears on screen and the Keypad will beep three times and flash a green LED once complete 3 14 1 2 Time Delay Count Mode Display Keypad For Keypads with a display there is an option to configure the time display for their respectiv...

Page 44: ... Most Urgent Lock In a single lock system the Time Delay status is for a single lock in a multi lock system the status will be provided for i the lock with the least amount of time remaining in the confirmation window or ii if no lock is in the confirmation window then the lock with the least amount of time remaining will be present in the delay window 4 Once the Time Delay period expires Lock sta...

Page 45: ...e This function is not available on the 701 series of Keypad Follow these steps to cancel a Time Delay on a non Display Keypad 1 While a safe lock is currently in a Time Delay using the Keypad input 74 Authorized User ID and Combination return key 2 The Keypad will beep three times and flash a green LED once complete 3 14 4 Allow Time Delay Override For a user to execute a Time Delay Override the ...

Page 46: ...lock number The screen will then provide timer feedback 4 There is no continuous feedback A key must be pressed to check on the Time Delay status When a key is pressed the Keypad will display the feedback for the most urgent lock 5 Press a key to exit the Time Delay Status screen 6 Input the User ID and Combination 7 From the Time Delay Menu select Open Lock a For multi lock systems select the cor...

Page 47: ...h using the Up and Down keys Will report the status as Dly Disable Dly Inactive o time Delay is enabled but the lock is not in the Delay Period nor the Confirmation Window Delay mm ss o the lock is in the Delay Period and shows the time in minutes and seconds using the Count Feedback mode assigned for the Delay Period Open mm ss o the lock is in the Confirmation Window and shows the time in minute...

Page 48: ...ed by a door with an installed lock These locks are installed as a part of a multi lock system With the inner door set as the Target Lock and the outer door as Lock 1 of the multi lock system Primary Lock an authorized user could be granted access to the outer area travel to the inner area and then be granted access to the inner area The Auto Open Sequence is activated under these conditions The A...

Page 49: ...ancelled and the Auto Open Sequence will begin Time Lock Schedule For an Auto Open Sequence only the schedules for the Target Locks are considered The schedule for Lock 1 is ignored during an Auto Open Sequence The schedule for Lock 1 is considered when Lock 1 is opened normally If the Target Lock is configured with both Time Delay and a Time Lock Schedule the Time Lock Schedule will be considered...

Page 50: ... up a key press is required to advance to the logon prompting Battery low warning will appear briefly before the opening of the Target Lock accompanied by LED flashes and beeps if buzzer enabled Battery Level critical If reported by the lock at wake up no further actions are possible until the battery is replaced If critical battery level is detected as a result of opening Lock 1 it will be report...

Page 51: ...ight of any specified Holiday Note If Time Date is not set after a prolonged power outage access Time Lock Schedules cannot be enforced and may result in the inability to open the lock until the time date is set For more information refer to section 3 17 Time Date Rules in LA GARD 700 Series Locks before using Time Lock Schedules Follow these steps to Assign or View Access Schedules or Holidays 1 ...

Page 52: ...PC communication c Adjusted by DST tables if DST is observed DST tables are the government time zone rules that allow the locality to change time on certain time periods of the year Locks can accept changes via the keypad a Local time can be entered based on rules on the system and converted to UTC and stored as UTC b Time zone setting and DST tables cannot be changed via the keypad Those settings...

Page 53: ...ge range for the 700 series FOB is between 2 1 and 2 3 volts The Low Battery warning can be observed in the feedback behavior When the battery voltage drops below 2 1 the Critical Low Battery warning will be observed in the feedback behavior and No attempt will be made to connect to the Entry Successful Identification FOB Low Battery 1 Upon Button Press Keypad LED Flash Yellow Orange Both Green an...

Page 54: ...mands and Appendix D contains 702 model commands The failed error will be 3 red LED flashes and 3 low beeps 5 LA GARD Software Note The LA GARD Software is not UL evaluated The LA GARD software is a multi faceted client that manages Users Schedules and Systems to be used in concert with LA GARD safe locks and Keypads This section outlines certain software functions Review the software online help ...

Page 55: ...he drop down menu 5 Select Program from the left hand column 6 Check the box beside User Changes 7 Connect the Keypad to the PC by doing the following a Plug the 700 Series USB Dongle into the USB Port of the PC b Plug the USB connector end of the cable into the dongle c Plug the mini USB end of the cable into the mini USB port on the Keypad 8 On the Keypad enter a valid User ID and the correspond...

Page 56: ...mini USB port on the Keypad 2 On the Keypad enter a valid User ID and the corresponding combination 3 From the LA GARD Software Main Menu select Settings 4 Fill out the following information in the software s Firmware Update sub menu Port From the drop down menu select the applicable comms port Firmware File Use the Select File button to navigate through the computer to find the firmware update fi...

Page 57: ...e into the dongle c Plug the mini USB end of the cable into the mini USB port on the Keypad 7 On the Keypad enter a valid User ID and the corresponding combination 8 Using the Arrow buttons on the Keypad navigate through the Main Menu and select PC Link by pressing the return key The top of the Keypad will illuminate red 9 In the software client PC Link window use the dropdown to select the User I...

Page 58: ...lect the PC Link icon 6 Double check the COM port or select a different port with the drop down menu 7 Select Program from the left hand column 8 Check the boxes beside Holidays and Schedules 9 Connect the Keypad to the PC by doing the following a Plug the 700 Series USB Dongle into the USB Port of the PC b Plug the USB connector end of the cable into the dongle c Plug the mini USB end of the cabl...

Page 59: ...ntial Mode Changed 8 Time Delay Values Changed 33 PC Link Enabled 9 Audits viewed Via Keypad or Software 34 PC Link Disabled 10 Lock Opened 35 RTC Time Reset 11 Lock Uninstalled 36 Battery Good 12 Time Delay Overridden with FOB user 37 Lock Firmware Update Started 14 User Added Modified or Deleted 38 Keypad Firmware Update Started 17 Keypad Reinstalled 39 Time Delay Override Enabled 18 Bolt Opened...

Page 60: ...tions to the input line interpretation Override Dual User Override Time Delay Fixed Install issue where prior SW installer installed to a specific user and not to all users in a machine Fixed Holiday creation on leap day failure Other various bug fixes Important Notes o To use this SW one must uninstall prior SW V 1 0 1 0 You may uninstall via the new installer package or uninstall via the MS Sett...

Page 61: ... Brazilian Added restriction to change Master User combination if default value Changed default DST observed setting per time zone selection Fixed Observed DST setting comparison when merging lock system and database settings Fixed other minor bugs Keypad Firmware Version Number Release Date Details 1 0 0 3 Initial Version 28 Oct 2020 Models 701 702 703 704 705 Support for o Deadbolt lock o Swingb...

Page 62: ...locked situation for the Manager to be able to immediately change the definition Added ability to change combination on uninstalled display model keypads Added feedback when Wrong Try Penalty period has completed Added ability to see system information if not installed for keypad models with a display Added enforcement for Master User to change combination when installed Also that the Master User ...

Page 63: ...odels 701 and 702 in uninstalled mode o Auto open lock feature o Additional definitions to the input line interpretation Override Dual User Override Time Delay Adjusted timing of alarm output signal with remote disable signal Various other bug fixes Notes about FW updating o It is strongly recommended that all locks and keypad have the latest FW available If the desire is to use the new features t...

Page 64: ...ely change the definition Added ability to change combination on uninstalled display model keypads Added feedback when Wrong Try Penalty period has completed Added ability to see system information if not installed for keypad models with a display Added enforcement for Master User to change combination when installed Also that the Master User cannot set combo back to the factory default Added othe...

Page 65: ...itial Set Up Commands for 1 Manager 1 Standard User The commands below are shown with the as the key press for waking the system When not needed the lock will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your command Action Command String Result Open the container using the Factory Default Open Code of 1 Keep the container open while perf...

Page 66: ...7 for 7 digit 11 00 ID _ _ _ _ _ _ _ _ Combo 8 for 8 digit 11 00 ID _ _ _ _ _ _ _ _ Combo 9 for 9 digit Master Only Note Impact to existing user combinations Keypad Lock Combo length changed for Manager and Standard Users Note Master Combo length does not change from 8 characters Changing the Combo Length will impact existing user combos Use the Master to Reset User combos after changing the Combo...

Page 67: ...ed Master requires 8 Keypad Lock Combination Changed Open Lock Single User _ _ ID _ _ _ _ _ _ Combo Manager or Standard User with Privilege Keypad Lock Opens User Administration Commands The commands below are shown with the as the key press for waking the system When not needed the lock will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for y...

Page 68: ...ck User will have new Initial Combination User should change combination for first use Uninstall Reinstall Reset Keypad and Lock The commands below are shown with the as the key press for waking the system When not needed the lock will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your command Action Command String Requirement Result Reins...

Page 69: ...he commands below are shown with the as the key press for waking the system When not needed the lock will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your command Audit Events shown below are not recorded for the 701 Models Action Command String Result Open the container using the Factory Default Open Code of 1 Keep the container open wh...

Page 70: ... Combination Length 11 11 00 ID _ _ _ _ _ _ _ _ Combo 6 for 6 digit 11 00 ID _ _ _ _ _ _ _ _ Combo 7 for 7 digit 11 00 ID _ _ _ _ _ _ _ _ Combo 8 for 8 digit 11 00 ID _ _ _ _ _ _ _ _ Combo 9 for 9 digit Master Only Note Impact to existing user combinations Keypad Lock Combo length changed for Manager and Standard Users Note Master Combo length does not change from 8 characters Changing the Combo L...

Page 71: ...r 702 Only Keypad Lock Backlight is On Off Set Local Time 65 702 Only 65 _ _ ID _ _ _ _ _ _ _ _ Combo YYMMDD HHmm YY Year MM Month HHmm Hour Minutes 24 hours Master or Manager 702 Only Keypad Lock Time Set Audit Event 2 Recorded Enable Disable Modify Time Delay 72 702 Only to Enable 72 _ _ ID _ _ _ _ _ _ _ _ Combo XX YY XX Delay Period Minutes 1 99 YY Confirmation Window Minutes 1 60 to Disable 72...

Page 72: ... apply to manager 12 00 ID _ _ _ _ _ _ _ _ Combo 2 Dual User does apply to manager Master Only 702 Only Keypad Lock User Mode is set and defined as selected Audit Event 30 Recorded Enable Disable Duress Mode 14 702 Only 14 00 ID _ _ _ _ _ _ _ _ Combo 0 to Disable 14 00 ID _ _ _ _ _ _ _ _ Combo 1 to Enable Master Only 702 Only Keypad Lock Duress Mode is Disabled Enabled Operation Commands The comma...

Page 73: ...uired Open Lock Dual User 702 Only _ _ ID _ _ _ _ _ _ Combo _ _ ID _ _ _ _ _ _ Combo Signal Duress 1 1 last digit of combination 702 Only Alarm box and Alarm Connectivity required for Silent Alarm Manager or Standard User with Privilege Keypad Lock Combination Changed Audit Event 10 Recorded for successful Unlock Event 21 when Unlocked with TDO Event 23 when Unlocked with Duress Combo Event 18 Bol...

Page 74: ... ID _ _ _ _ _ _ New Combo 4 1 Audit Only 50 _ _ ID _ _ _ _ _ _ Combo _ _ New ID _ _ _ _ _ _ New Combo 4 2 Open Audit 50 _ _ ID _ _ _ _ _ _ Combo _ _ New ID _ _ _ _ _ _ New Combo 4 3 Open TDO 50 _ _ ID _ _ _ _ _ _ Combo _ _ New ID _ _ _ _ _ _ New Combo 4 5 Open Audit TDO 50 _ _ ID _ _ _ _ _ _ Combo _ _ New ID _ _ _ _ _ _ New Combo 4 7 Master Only Manager must be created by Master Combination Length...

Page 75: ... beep signaling that the lock is ignoring that key and waiting for your command Audit Events shown below are not recorded for the 701 Models Action Command String Requirement Result Reinstall Keypad 32 32 _ _ ID _ _ _ _ _ _ _ _ Combo Open Privilege Required Keypad Alternating Red and Green Flashes indicate the same Keypad Model is not paired Success indicated with Lock Lock is Installed to Keypad ...

Page 76: ...dormakaba USA Inc System User Guide 7040 1121 Rev E 10 22 75 dormakaba USA Inc 1525 Bull Lea Rd Lexington KY 40511 888 950 4715 www dormakaba com ...