dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 65
Step 3
Change
Combinations
(Recommended)
Change
Manager
Combination:
#52
Change
Standard User
Combination:
#52
#52 01 (ID) 123456 (Combo)
01 (ID) _ _ _ _ _ _ (New 6 Digit Combo)
01 (ID) _ _ _ _ _ _ (New Combo)
#52 02 (ID) 123456 (Combo)
02 (ID) _ _ _ _ _ _ (New 6 Digit Combo)
02 (ID) _ _ _ _ _ _ (New Combo)
Keypad:
Lock:
Combination Changed
Keypad:
Lock:
Combination Changed
Other System Function Settings
The commands below are shown with the as the key press for waking the system. When not needed the lock
will respond with a short red flash and low beep signaling that the lock is ignoring that key and waiting for your
# command.
Action
Command String
Requirement Result
Set/Change
Combination
Length:
#11
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 6 for 6 digit
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 7 for 7 digit
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 8 for 8 digit
#11 00 (ID) _ _ _ _ _ _ _ _ (Combo) 9 for 9 digit
Master Only
Note:
Impact
to existing
user
combinations
Keypad:
Lock:
Combo length changed
for Manager and Standard
Users.
Note:
Master Combo length
does not change from 8
characters. Changing the
Combo Length will impact
existing user combos.
*
Use the Master to Reset
User combos after changing
the Combo Length. Users
should then change their
combo for first use.
Set Force
Change
Combo
Force Combination Change On/Off:
#17 (Default Off)
Do Not Require Combo Change:
#17 00 (ID) _ _ _ _ _ _ _ _ (Combo) 0
Require Combo Change:
#17 00 (ID) _ _ _ _ _ _ _ _ (Combo) 1
Master Only
Keypad:
Lock:
Require Combination
Change on First Use will be
On/Off
Set Buzzer
On/Off:
#41
#41 _ _ (ID) _ _ _ _ _ _ (Combo) 0
for Buzzer Off
#41 _ _ (ID) _ _ _ _ _ _ (Combo) 1
for Buzzer On
Master or
Manager
Keypad:
Lock:
Buzzer is On/Off
Enable FW
Update Port:
#99
#99 _ _ (ID) _ _ _ _ _ _ (Combo)
Master or
Manager
Keypad:
Lock:
Firmware can be
updated by 700 Series