dormakaba USA Inc. System User Guide 7040.1121 Rev E 10/22 | 70
Enable FW
Update Port:
#99
#99 _ _ (ID) _ _ _ _ _ _ (Combo)
Master or
Manager
Keypad:
Lock:
Firmware can be
updated by 700 Series
Software.
Audit:
Event 37/38
Recorded
Open PC
Link:
#30
#30 _ _ (ID) _ _ _ _ _ _ (Combo)
Master,
Manager, or
User with
Privilege
Keypad:
Green LED blinks during
data transfer
Lock:
Can be configured
by software
Audit:
Event 33 & 34
Recorded
Note:
702 models support
PC LINK Compare,
Programming and Audit
Features not available on
701
Set Backlight
to On/Off:
#40
(702 Only)
#40 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) 0 for Off
#40 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) 1 for On
Master or
Manager
(702 Only)
Keypad:
Lock:
Backlight is On/Off
Set Local
Time:
#65
(702 Only)
#65 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) YYMMDD HHmm
YY=Year, MM=Month, HHmm=Hour/Minutes (24 hours)
Master or
Manager
(702 Only)
Keypad:
Lock:
Time Set
Audit:
Event 2 Recorded
Enable/
Disable/
Modify Time
Delay:
#72
(702 Only)
to Enable: #72 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) XX YY
XX=Delay Period Minutes 1-99, YY=Confirmation Window Minutes 1-
60
to Disable: #72 _ _ (ID) _ _ _ _ _ _ _ _ (Combo) 00 01
00=Delay Period Minutes, 01=Confirmation Window Minutes
Master or
Manager
(702 Only)
Keypad:
Lock:
Time Delay is
Enabled with selected
Delay Period and
Confirmation Window or
Disabled
Audit:
Event 8 Recorded
Note:
When modifying
time delay settings to
disable or reduce Delay
Period, the new time
delay setting will not be
effective until the lock is
opened successfully under
the previous delay
requirement