22637300
I) Readjust the speed of the unit to its rated no-load value.
ADJUSTMENT
SETTING
G25, G40, G60, G70, G80, G90, G125, G145, G185-R438 AREP
1
ST 1 (Sensing jumper - single phase)
Not cut
2
ST2 (response Time jumper - normal)
Not cut
3
ST3 (Frequency - 60 Hz)
60 Hz Installed
4
ST4 (External potentiometer)
Ext pot wired per wiring diagram
5
ST5 (LAM jumper - with LAM)
Installed
7
ST9 (AREP)
Not cut
8
ST10 (Voltage drop amplitude jumper)
13% position (lower)
9
ST11 (Underfrequency knee point jumper - 58 Hz)
Not cut
10
P1 (Droop - 0%)
Fully counter-clockwise
11
P2 (Voltage)
Set to limit remote pot to 504V max output
12
P3 (Stability)
Center position
13
P5 (Excitation current - 10A maximum)
Fully clockwise
G240, G290, G450, G570 - R448 AREP
1
ST 1 (Sensing jumper - single phase)
Not cut
2
ST2 (response Time jumper - normal)
Not cut
3
ST3 (Frequency - 60 Hz)
60 Hz Installed
4
ST4 (External potentiometer)
Ext pot wired per wiring diagram
Summary of Contents for G10WMI-2D-T2
Page 2: ...2 ...
Page 5: ...22637300 5 Drawbar Notice ...
Page 7: ...22637300 7 Safety Symbols ...
Page 11: ...Safety Symbols Operation Maintenance Manual 22637300 11 ...
Page 12: ...12 22637300 Always use genuine replacement parts ...
Page 13: ...22637300 13 Safety ...
Page 21: ...22637300 21 General Data ...
Page 28: ...28 22637300 ...
Page 29: ...22637300 29 Operating Instructions ...
Page 36: ...Operation Maintenance Manual Operating Instructions 36 22637300 20 18 19 21 22 ...
Page 54: ...Operation Maintenance Manual Operating Instructions 54 22637300 ...
Page 55: ...Operating Instructions Operation Maintenance Manual 22637300 55 ...
Page 65: ...22637300 65 Maintenance ...
Page 75: ...22637300 75 Alternator Installation and Maintenance ...
Page 103: ...Alternator Installation and Maintenance Operation Maintenance Manual 22637300 103 ...