Operation & Maintenance Manual
Operating Instructions
38
22637300
STARTING (KEY START MODELS)
CAUTION
!
Use the EMERGENCY STOP button ONLY in the event of an emergency.
NEVER use it for normal shut-down.
Verify the following:
1. All external electrical power requirements are turned “OFF”.
2. Main Breaker is “OFF”.
3. Battery Disconnect Switch “ON”
4. Ensure both the VOLTAGE SELECTOR (if equipped) and DIRECT HOOK-UP
terminal doors are closed.
5. Reset (pull to unlatch) Emergency Stop Button.
6. Turn the ENGINE START SWITCH to “PREHEAT” for maximum of 10 seconds
for cold weather starts.
7. Turn ENGINE START switch to “START”. Release after engine starts.
CAUTION
!
Do NOT use engine starting fluids.
DANGER
!
POWER is present upon cranking the engine.