SGE3500BSi
INVERTER
PORTABLE GENERATOR
15750112002
Page 1: ...SGE3500BSi SGE3500BSi SGE3500BSi SGE3500BSi INVERTER PORTABLE GENERATOR 15750112002 15750112002 15750112002 15750112002...
Page 2: ...PONENT IDENTIFICATION 5 CONTROLS 6 HOW TO ASSEMBLE WHEELS AND STOPPER 8 HOW TO OPERATE GENERATOR 8 PRE OPERATION CHECKS 11 STARTING THE ENGINE STOPPING THE ENGINE 15 MAINTENANCE 17 TROUBLE SHOOTING 24...
Page 3: ...others are very important We provided important safety messages in this manual and on the generator Please have an attention and read instruction carefully These words mean You will be killed or seri...
Page 4: ...less and odorless gas Breathing exhaust can cause loss of consciousness and may lead to death 2 If you run the generator in an area that is confined or even partially enclosed the air you breathe coul...
Page 5: ...d muffler cover becomes very hot during operation and remains hot for a while after stopping the engine Do not to touch the muffler and muffler cover while it is hot Let the engine cool before storing...
Page 6: ...CHANGE SWITCH INSTALL MODEL ONLY RECOIL STARTER GRIP ENGINE SWITCH PILOT LAMP OVER LOAD LAMP RESET SWITCH MUFFLER FUEL TANK CAP CARRYING HANDLE DC OUTPUT AC RECEPTACLE AC CIRCUIT BREAKER GROUND TERMIN...
Page 7: ...and gasoline when the engine is cold It can be opened and closed by operating the choke knob manually Pull the knob toward closed to enrich the mixture Circuit Breaker The Circuit breaker will automat...
Page 8: ...he engine switch will remain in the ON position If the Oil Alert system shuts down the engine refill engine oil Frequency Change Switch Install model only To change frequency let a switch slide with a...
Page 9: ...a building s electrical system can allow electrical current from the generator to backfeed into the utility lines Such backfeed may electrocute utility company workers or others who contact the lines...
Page 10: ...ddenly turn it off immediately Disconnect the appliance and determine whether the problem is the appliance or if the rated load capacity of the generator has been exceeded 3 Make sure that the electri...
Page 11: ...way from the battery Connect an attached battery cable to the DC outlet of the generator Connect the other end of the red lead of the battery charging cable to the positive battery terminal and the ot...
Page 12: ...recommended Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped Use a high quality detergent oil classified For Service SF SG SH SJ Use no special additi...
Page 13: ...the engine is refueled or where gasoline is stored 3 Do not overfill the fuel tank there should be no fuel in the filler neck After refueling make sure the tank cap is closed properly and securely Be...
Page 14: ...lended with alcohol or an ether compound to increase the octane These gasolines are collectively referred to as oxygenated fuels Some areas use oxygenated fuels to help meet clean air standards If you...
Page 15: ...e pump If you notice any undesirable operating symptoms switch to a conventional unleaded gasoline Fuel system damage or performance problems resulting from the use of an oxygenated fuel are not the r...
Page 16: ...choke knob to the CLOSE position Move the engine switch to the ON position Pull the starter recoil grip until compression is felt then pull briskly Do not allow the starter recoil grip to snap back R...
Page 17: ...g the Engine In an emergency To stop the engine in an emergency move the engine switch to the OFF position In normal use Move the engine switch to the OFF position Turn the fuel valve to the OFF posit...
Page 18: ...limited warranty does not cover MAINTENANCE SCHEDULE REGULAR SERVISE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First month or 5Hrs 3 Every 1mo...
Page 19: ...cause skin cancer if repeatedly left in contact with the skin for prolonged periods Although this is unlikely unless you handle used oil on a daily basis it is still advisable to thoroughly wash your...
Page 20: ...mable solvent to clean the filter element can cause a fire or explosion Use only soapy water or nonflammable solvent Never run the generator without the air cleaner Rapid engine wear will result Loose...
Page 21: ...th a feeler gauge Correct as necessary by carefully bending the side electrode The gap should be 0 76mm 0 03in Check that the spark plug washer is in good condition and thread the spark plug in by han...
Page 22: ...generator in extremely dusty areas Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion Use only soapy water or nonflammable solvent Loosen the air filter cov...
Page 23: ...MMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with fresh gaso...
Page 24: ...ea during this procedure 4 Change the engine oil 5 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil th...
Page 25: ...pilled fuel may ignite Is the fuel reach in No Clean the fuel line the carburetor Yes If the engine still does not start take the generator to an Authorized your dealer To check Remove the spark plug...
Page 26: ...s Replace the electrical appliance or equipment Take the electrical appliance or equipment to an electrical shop for repair Is the over load lamp Yes Push to reset switch Lighting AC power is ON No Ch...
Page 27: ...0VA DC Output 12V 8 3A Voltage Regulator Inverter Type Engine Model BRIGGS STRATTON I C6 5HP Type Air Cooled 4Cycle OHV Gasoline Engine Displacement 206cm3 Maximum Power Output 4 8kW 4000min 1 Others...
Page 28: ...DAISHIN DAISHIN DAISHIN DAISHIN INDUSTRIES INDUSTRIES INDUSTRIES INDUSTRIES LTD LTD LTD LTD 1520 1 Funatsuke Yoro cho Yoro gun Gifu 503 1382 Japan TEL 0584 36 0501 FAX 0584 36 0504...