background image

9510-065-D-3-10 - Draft - Not for Release

21

TIME 

DELA

EXIT 

LOOP 

LMT 

LMT 

REVERSE

LOOP

REV SENSE 

OPEN 

REV SENSE 

CLOSE 

ON 

2 3 

ON 

2 3 

4 5 

6 7 

NC 

NO 

P8 

P7 

P6 

4404-010

20 19 18 17 16 15 14 13 

12 11 

10 9  8  7  6 5  4  3  2  1 

Speed Brake

Plug P8

ON 

2 3 

ON 

2 3 

4 5 

6 7 

3.1 4404 Circuit Board Description and Adjustments 

SECTION 3 - ADJUSTMENTS 

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is 
complete. 

Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then 

turned back on for the new setting to take effect. 

Auto-close timer (when 
turned on) SW 1, switch 2. 

Dry relay contacts 
(terminals 11-12) can be 
set for Normally Open 
(NO) or Normally Closed 
(NC) operation by placing 
the relay shorting bar on the 
N.O. or N.C. pins respectively. 
SW 1, switches 4 and 5 must 
be set to control relay. See 
next page for descriptions. 

Auto-Close Timer 

Speed Controller

Adjustments

Dual Channel Loop Detector

Single Channel Loop Detector 

Dry Relay Contact 

Set the DIP-switches on the circuit 
board to the desired setting. See 
switch setting charts on next 2 pages. 

DIP-Switches 

SW 2 is Upside-Down on Board 

SW 1 is Upside-Down on Board 

LEDs 

Indicates that low voltage power is applied to the circuit board. 

Input LEDs

 should be OFF and will only 

illuminate when the input is activated. 

Limit LEDs

 will be on when the respective limit switch is activated. 

Adjust reversing 
sensitivity for 
open and close 
directions. 
Full counter 
clockwise for 
minimum 
sensitivity, full 
clockwise for 
maximum 
sensitivity. 
See page 25. 

Reverse 
Sensors 

Motor

Plug P6

Limit Switch Plug P2 

Self-test (when turned on) 
SW 2, switch 1. 

CAUTION 

Do not

 run self-test with the 

operator connected to the gate. 
The drive chain must be 
disconnected before running 
the self-test. This feature is 
designed for bench testing 

ONLY

Self-Test

UL 325 Terminal 

Power LED 

LMT

Limit LEDs 

Input LEDs 

Input LED 

Input LEDs 

9410

9409

SW 1 is Upside-Down on Board 

1  1 

ON 

2

34

56 6

 7

8  8 

SW 2 is Upside-Down on Board 

ON 

23

4

1 23 

Adjust from 1 second  
(full counter-clockwise) to 
approximately 23 seconds 
(full clockwise). 

NC 

NO 

1  1 

ON 

23

45

6  6 7 7

 8 8

 

SW 1 is Upside-Down on Board 

Min Max 

CLOSE 

Sensitivity 

OPEN 

1 ft/s

.5 ft/s

0 ft/s

2 ft/s

1.5 ft/s

2 ft/s

1 ft/s

0 ft/s

4 ft/s

3 ft/s

Min

Max

Speed

See page 26 for 
description.

Summary of Contents for Series 9500

Page 1: ...t ions SE RIO US INJ UR Y OR DE AT H WARNING MOVING GATE CAN CAUSE Operate gate only when gate area is in sight and free of people and obstructions Do not allow children to play in gate area or operat...

Page 2: ......

Page 3: ...ided Gear Ratio Traveling Speed Amp Horsepower Voltage Phase Max Gate Weight Installed Level Max Gate Length Installed Level Brake Use this manual for the 9500 series operators with circuit board 4404...

Page 4: ...0 10 10 11 12 13 13 14 14 15 16 17 18 19 20 1 1 Gate Hardware 1 2 Removing Cover 1 3 Underground Conduit Requirements 1 4 Concrete Pad Description 1 5 Mounting Operator and Chain 1 6 Installation of C...

Page 5: ...lt In Controls and Reset Buttons Description 4 2 Shutdown Conditions Soft Shutdown Hard Shutdown 4 3 Manual Gate Operation 5 1 Maintenance 5 2 Built In Diagnostic Tests 5 3 Troubleshooting 5 4 Accesso...

Page 6: ...parate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire p...

Page 7: ...talled used and maintained serious injuries or death can result Be sure that the installer has instructed you on the proper operation of the gate and gate operator system Be sure that the installer ha...

Page 8: ...eral public in which unauthorized access is prevented via supervision by security personnel This table illustrates the entrapment protection requirements for each of the four UL325 classes A Inherent...

Page 9: ...intended for vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system th...

Page 10: ...ge A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate support post and the gate frame when the gate is in either the fu...

Page 11: ...e potential of the gate closing on vehicular or other traffic that loops cannot sense Installed on the fence to help minimize the potential of entrapment between the gate and fence A filler post or ba...

Page 12: ...r High Voltage Power Sweeps Concrete Pad Concrete Pad 3 4 Inch Minimum Primary Operator Position Secondary Operator Position SECTION 1 INSTALLATION Prior to beginning the installation of the slide gat...

Page 13: ...View End View Front View Back Anchor Foot Front Anchor Foot Concrete Pad Conduit Area Front Anchor Foot Front Anchor Foot Back Anchor Foot Above Ground Re bar Re bar Re bar Sleeve Anchors Note Minimu...

Page 14: ...to gate Chain brackets MUST be mounted so the chain remains the same height as it is on the idler wheels Connect Chain to Chain Bracket Positioning Operator and Chain Brackets Attach Operator to Concr...

Page 15: ...or longer gates to support the weight of the chain DoorKing offers a chain tray and supporting brackets in sections to fit any length gate DoorKing P N 2601 270 10 Ft section Supporting Bracket Suppor...

Page 16: ...re attempting to connect any wiring to the operator be sure that the circuit breaker in the electrical panel is in the OFF position Permanent wiring must be installed to the operator as required by lo...

Page 17: ...setting See page 24 for limit nut descriptions 2 Operation of relay is dependent on setting of SW 1 switches 4 and 5 See page 22 for DIP switch function descriptions Relay contacts can be set for Nor...

Page 18: ...sing edge sensor has been activated and the gate is traveling to the close position but the close reversing edge sensor gets activated the gate will stop and enter a soft shutdown condition 4 Close Ed...

Page 19: ...ens gate Important Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls Outdoor or easily accessible controls shoul...

Page 20: ...Engaged 2 6 Auxiliary Device Wiring Gate Tracker DoorKing Access Control System Model 1833 1835 1837 or 1838 tracker system can be connected This system can keep track of gate operator cycle count sho...

Page 21: ...les without having to use a transmitter or keypad The exit loop can be placed 20 100 feet away from the gate so the gate has started opening or has completely opened by the time you drive up to it Rev...

Page 22: ...ugh path while gate is moving Read owner s manual and safety instructions SERIOUS INJURY OR DEATH Secondary Entrapment Protection Devices Secondary Operator Primary Operator To Close Photo 2 To Open E...

Page 23: ...cuit board to the desired setting See switch setting charts on next 2 pages DIP Switches SW 2 is Upside Down on Board SW 1 is Upside Down on Board LEDs Indicates that low voltage power is applied to t...

Page 24: ...to close gate Auto close timer is ON Adjustable from 1 23 seconds to close gate Self Test Gate Opens Uphill 3 Gate Opens Downhill 6 Relay activates and LED is ON when the gate is fully open Relay act...

Page 25: ...he board will be activated This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving or turning on a green light when the gate is full open...

Page 26: ...ts After adjusting the limit nuts be sure that the lock plate is engaged in the slots on the limit nuts to prevent them from rotating The slow down limit assembly will move up or down 3 4 inch DO NOT...

Page 27: ...tandards The gate will reverse direction upon encountering an obstruc tion in either the opening or closing gate cycle For the reverse system to function correctly the gate must be properly installed...

Page 28: ...e gate speed The digital readout on the speed controller will display the gate speed The 10 1 gear reducer 9500 models are equipped with a speed brake It is automatically controlled by the speed contr...

Page 29: ...repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTIONS Unlock If padlocked and remove the cover See section 1 2 Removing cover on...

Page 30: ...ed The automatic close timer will not close the gate Example 3 Vehicle arrives at exit loop and gate runs towards the open position If the inherent entrapment protection gets activated during this ope...

Page 31: ...catch 3 Lift cover off vertical BE CAREFUL not to hit internal components with cover Idler Wheels Padlock Not Provided 1 2 3 Manually Crank Remove the Cover 1 2 Insert the supplied manual hand crank i...

Page 32: ...ould they become entrapped in the gate When servicing this gate operator always turn power OFF Operator Component Maintenance Monthly Interval 6 3 12 Alarm Chain Fire Dept Gate Loop s Release Primary...

Page 33: ...there are no shorted or open control wires from the keying devices to the gate operator If a keying device fails to open the gate press the Key Switch or momentarily jumper across terminals 1 and 5 on...

Page 34: ...ate operator and check that the gate slides freely without any binding Check the loop detector LEDs and input LEDs Any that flash ON will cause the gate to reverse Replace the circuit board Operator h...

Page 35: ...e integrity of ground loops P N 9401 045 3 Button Control Station Provides open close stop manual operation of the gate Stand Alone Box P N 1200 006 Interior fits in single gang box P N 1200 007 Inter...

Page 36: ...enue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 www doorking com Owner s Manual Series 9500 Series 9500 Maximum Security Heavy Duty Vehicular Slide Gate Operators 9510 065 D...

Reviews: