3.1 4404 Circuit Board Description and Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
Auto-close timer (when
turned on) SW 1, switch 2.
Dry relay contacts
(terminals 11-12) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next page for descriptions.
Auto-Close Timer
Speed Controller
Adjustments
Dual Channel Loop Detector
Single Channel Loop Detector
Dry Relay Contact
Set the DIP-switches on the circuit
board to the desired setting. See
switch setting charts on next 2 pages.
DIP-Switches
SW 2 is Upside-Down on Board
SW 1 is Upside-Down on Board
LEDs
Indicates that low voltage power is applied to the circuit board.
Input LEDs
should be OFF and will only
illuminate when the input is activated.
Limit LEDs
will be on when the respective limit switch is activated.
Adjust reversing
sensitivity for
open and close
directions.
Full counter
clockwise for
minimum
sensitivity, full
clockwise for
maximum
sensitivity.
See page 25.
Reverse
Sensors
Motor
Plug P6
Limit Switch Plug P2
Self-test (when turned on)
SW 2, switch 1.
CAUTION
Do not
run self-test with the
operator connected to the gate.
The drive chain must be
disconnected before running
the self-test. This feature is
designed for bench testing
ONLY
.
Self-Test
UL 325 Terminal
Power LED
LMT
Limit LEDs
Input LEDs
Input LED
Input LEDs
9410
9409
SW 1 is Upside-Down on Board
1 1
ON
2
34
56 6
7
8 8
SW 2 is Upside-Down on Board
1
ON
23
4
1 23
Adjust from 1 second
(full counter-clockwise) to
approximately 23 seconds
(full clockwise).
NC
NO
1 1
ON
23
45
6 6 7 7
8 8
SW 1 is Upside-Down on Board
Min Max
CLOSE
Sensitivity
OPEN
1 ft/s
.5 ft/s
0 ft/s
2 ft/s
1.5 ft/s
2 ft/s
1 ft/s
0 ft/s
4 ft/s
3 ft/s
Min
Max
Speed
See page 26 for