9510-065-D-3-10 - Draft - Not for Release
17
NC
NO
P7
20 19 18 17 16 15 14
13
12 11 10 9
8
7
6
5
4
3 2 1
2.5 Control Wiring
Red Full Open
Green Close
White Com
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
3-Button Control Station
DoorKing ONLY
Functions
ONLY
during gate closing cycle.
SW 1, switch 7:
OFF
- Reverses.
ON
- Stops then closes
(ON setting typically used to
help prevent tailgating).
NOT secondary entrapment protection.
Note: All stand-alone and
telephone entry devices must
use a separate power source.
#5-Connected device partially opens gate (See page 24).
#4-Connected device fully opens gate.
Important:
Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while
operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use.
Photocells
Terminal #5 Connection
#1-Com
#1-Com
Com
To #4 or #5
#2 or #5-Relay
#3-24 volt, 250 mamp. max.
SW 1, switch 7 must be
ON
.
Secondary entrapment devices will
reverse and open the gate to the
middle limit nut setting (Partial open)
if opening device is connected to
terminal #5. See page 24.
#1-Relay Com
#2 or #5-Relay N.O.
#1-24 Volt Power Com
#3-24 Volt Power
4-Wire Radio Receiver
1
ON
23
45
6
7
8
SW 1 is Upside-Down on Board
1
ON
23
45
6
7
8
#2-Fully opens gate.
3-Wire Radio Receiver
Fire Box
Auxiliary Common
Terminal
SW 1 is Upside-Down on Board
4404-010
Summary of Contents for Series 9500
Page 2: ......