CONFIGURING THE HEAT PUMP
The
DUAL CLIMA
heat pump is supplied from factory configured to provide Heating, Cooling and
DHW modes. In case the installation does not have any of these services allowed,
they must be
disabled
by adjusting the DIP-Switch (
SW1
) of the control PCB (see
"Electrical Diagrams"
). When any
mode is disabled, all the settings and parameters related to this operating mode will disappear from
the main board display.
Before accessing and adjusting the DIP-Switch
disconnect
the main power supply of the heat pump.
To access the DIP-Switch, remove the front door of the machine and remove the cover of the
electronic boards.
Disabling the DHW mode
If the installation does not have an storage tank for the production of DHW, this
mode must be disabled. To do this, set the switch
SW1-6
to ON.
Disabling the Heating mode
If the installation does not have a water circuit ready to operate in heating mode
(underfloor heating, radiators, etc.), this mode must be disabled. To do this, set
the switch
SW1-7
to ON.
Disabling the Cooling mode
If the installation does not have a water circuit ready to operate in the cooling
mode (cooling floor, fan coils, etc.), this mode must be disabled. To do this, set
the switch
SW1-8
to ON.
IMPORTANT: Keeping a mode enabled without the installation being prepared to operate with
it may cause a malfunction of the heat pump and SERIOUS damage to the
installation.
11
TECHNICAL MENU
The electronic controller of the
DUAL CLIMA
pump has a menu of technical parameters, with which
the operation of the pump is managed in the gas and water circuits. Any incorrect adjustment of any
of these may cause a breakdown and/or rupture of the machine. Therefore, most parameters of the
technical menu should only be modified by personnel authorised by
DOMUSA TEKNIK
. Nevertheless,
some technical parameters (described in previous sections) will be useful for the installer and/or the
user and should be adjusted by them, depending on the thermal characteristics and performance
desired in the home.
To access the technical menu parameters, keep buttons
+
pressed simultaneously for 3 seconds
(until you hear a beep). The display will show the first parameter
P00
along with its current value. Use
buttons
to select the desired parameter and press
to access its current value. The display will
show only the value flashing. Use buttons
to select the desired value and press
to confirm
and return to the technical menu. After finishing the parameter adjustment, press
to exit the
Technical menu.