DUAL CLIMA
8
4.7
Cooling and DHW mode
+
This mode will be selectable only if the heating/cooling installation is ready to operate in Cooling
mode (cooling floor, fan coils, etc.); the installation has a connected domestic hot water tank and
the heat pump is configured for it.
This operating mode is the combination of the Cooling and DHW simultaneously. When the DHW
demand is enabled, the heat pump will disable the Cooling mode and will enable the Domestic Hot
Water production mode, with the production of priority DHW relating to the cooling of the
heating/cooling installation. Once the desired DHW temperature is reached, the heat pump will re-
enable the Cooling mode.
4.8
Heating and DHW mode
+
This mode will be selectable only if the installation has a Domestic Hot Water tank connected and
the heat pump is configured for it.
This operating mode is the combination of the Heating and DHW modes simultaneously. When the
demand for DHW is activated, the heat pump will disable the Heating mode and will enable the Hot
Domestic Water production mode, with the production of priority DHW relating to the heating of
the heating/cooling installation. Once the desired DHW temperature is reached, the heat pump will
re-enable the Heating mode.
4.9
Anti-Legionella function
This function prevents the proliferation of Legionella bacteria in the domestic hot water stored in
the tank, so it will only be available if the installation has a connected Domestic Hot Water tank and
the heat pump is configured for it. In addition, in order to make the function effective, it will be
essential for the tank to have a heating component installed, in order to reach the temperatures
required to eradicate the bacteria.
The function will periodically raise the temperature of the Domestic Hot Water from the tank to a
temperature of 60~70 ºC. To do this, the desired temperature and periodicity can be selected (see
"Temperature Selection"
). This function will be activated regardless of the operating modes that are
activated at the time of starting, even when the heat pump is in Standby mode.
In addition, it is possible to activate the function manually, keeping the button
pressed during 5
seconds. Once the function is activated, it is not possible to stop it and it will have to wait until it
finished, in order that the machine returns to its normal operation.