27
9.6.7
Connecting a Heating auxiliary electrical heater (E2)
The
DUAL CLIMA
heat pump allows the connection of a heating resistor for Heating (optional).
Within the wide range of accessories for heat pumps,
DOMUSA TEKNIK
offers the optional HP
Hydraulic Kit that includes a heating electrical heater (2,500 W).
The electrical connection of the heater will be made between terminals
E2L
and
E2N
(Neutral) of
the component terminal of the heat pump.
The relay that activates the electrical heater has a maximum capacity of 20 A of consumption.
Therefore, to connect a heater exceeding 4,500 kW, a contactor must be interposed between the
terminals of the power terminal and the heater.
IMPORTANT: Before carrying out any work on the electrical installation of the heat pump,
always ensure it is disconnected from the mains.
9.6.8
Connecting the installation pump (C5)
The
DUAL CLIMA
heat pump allows the connection of a circulation pump (
C5
) for the
Heating/Cooling installation, whose operation will be managed by a room sensor (
IN6
) connected
to the machine (see
"Connecting a Room Sensor"
).
The electrical connection of the pump will be made between terminals
C5L
and
C5N
(Neutral) of
the component terminal of the heat pump.
IMPORTANT: Before carrying out any work on the electrical installation of the heat pump,
always ensure it is disconnected from the mains.