9.6.10
Connecting the room thermostat
The
DUAL CLIMA
heat pump incorporates an
IN7
connection in the input terminal (located on the
electronic controller board) prepared for the connection of a room chrono-thermostat or room
thermostat (see
"Electrical Diagrams"
), which will stop the heating and/or cooling service of the
heating/cooling installation, turning off the operation of the heat pump when the desired
temperature in the home is reached. The operation with the room thermostat will not affect the
DHW service, keeping it enabled regardless of the status of the thermostat.
The IN7 terminals are supplied from the factory with a jumper between them, so it will be necessary
to remove the jumper before connecting the room thermostat. To disconnect the jumper and
connect the thermostat, press the upper screws with a thin flat screwdriver to release the cables
and stop pressing to reattach them.
IMPORTANT: Before carrying out any work on the electrical installation of the heat pump,
always ensure it is disconnected from the mains.
9.6.11
Connecting the room sensor
The
DUAL CLIMA
heat pump incorporates an
IN6
connection in the input terminal (located on the
electronic controller board) prepared for the connection of a room temperature sensor to measure
the temperature inside the home (see "Electrical Diagrams"), which will allow the circulation pump
of the heating/cooling installation (
C5
) to be stopped when the desired temperature in the home is
reached, no longer delivering heat or cold to the room. The heat pump will remain activated until it
reaches the setpoint temperature selected for it (see "Temperature Selection"). The operation with
the room sensor will not affect the DHW service (if any), keeping it enabled regardless of the
temperature inside the home.
The IN6 terminals are supplied from the factory with an electronic resistor between them, so it will
be necessary to remove it before connecting the room sensor. To disconnect the resistor and
connect the sensor, press the upper screws with a thin flat screwdriver to release the cables and
stop pressing to reattach them.
IMPORTANT: Before carrying out any work on the electrical installation of the heat pump,
always ensure it is disconnected from the mains.