Instructions manual
/ MDT Series & MDTC38
60429 08/21
48
Forward run time limit
Unit
Range
Initial
Sec
0 - 60
10
Description
Run limit to forward rotation
–
It prevent the continuous running over the
preset time. The driver stops automaticaly at the preset time and
provides the pattern NG with error code
Reverse run time limit
Unit
Range
Initial
Sec
0 - 60
10
Description
Run limit to reverse rotation
–
It prevent the continuous running over the
preset time. The driver stops automaticaly at the preset time and
provides the pattern NG with error code
Motor stall time
Unit
Range
Initial
Sec
0,1
–
0,5
0,2
Description
Immediate stop when motor is stalled.- It prevent the continuous time
going against the motor stall for over heat protection
Error display reset time
Unit
Range
Initial
sec
0 ~ 10
1,0
Description
Error display and reset after the below set time
Value 0 : manual reset with RESET button
Fastening OK signal time
Unit
Range
Initial
ms
0 ~ 500
200
Description
Signal output time setting longer than 200ms which is factory setting.
Shorter time than factory setting doesn’t work..
Screw type
Unit
Range
Initial
CW - CCW
CW
Description
Set tightening rotation direction for each preset
Judged fasten minimum turn
Unit
Range
Initial
turn
0 ~ 5
0
Description
Turns out of judgement
Fastening stop error
Unit
Range
Initial
YES - NO
NO
Description
NO : does not create any NG when the tool stops without fully tightening
by torque up.
Alarm sound control
Unit
Range
Initial
YES NO
YES
Description
Activation of noise alarm
–
stops when reset (timer or manual)
Torque calibration
Unit
Range
Initial
%
90 ~ 110
100
Description
It is the master calibration for whole range of tool.
Saved in the tool memory and effective on another controller.
The F/R switch should be at Reverse position before writing the new
value.
For details, please refer to chapter 9
Summary of Contents for MDT Series
Page 1: ...INSTRUCTIONS MANUAL MDT series MDTC38 ...
Page 12: ...Instructions manual MDT Series MDTC38 60429 08 21 12 ...
Page 14: ...Instructions manual MDT Series MDTC38 60429 08 21 14 MTD3206 A L MDTH3206 A L MDTH3206 Q L ...
Page 16: ...Instructions manual MDT Series MDTC38 60429 08 21 16 MDT3245 3264 Q L MDTH3245 3264 Q L ...
Page 19: ...Instructions manual MDT Series MDTC38 60429 08 21 19 MDTP3245 3264 Q D MDTP3245 3264 Q U ...
Page 33: ...Instructions manual MDT Series MDTC38 60429 08 21 33 ...
Page 34: ...Instructions manual MDT Series MDTC38 60429 08 21 34 ...
Page 45: ...Instructions manual MDT Series MDTC38 60429 08 21 45 7 10 Controller settings ...
Page 47: ...Instructions manual MDT Series MDTC38 60429 08 21 47 ...
Page 49: ...Instructions manual MDT Series MDTC38 60429 08 21 49 ...
Page 54: ...Instructions manual MDT Series MDTC38 60429 08 21 54 Outputs ...
Page 82: ......
Page 83: ......
Page 84: ... DOGA DOC 60429 08 21 ...