734N-WIFI Installation and Programming Guide     |     Digital Monitoring Products, Inc.

CERTIFICATIONS

FCC Part 15 ID: CCKPC0136
Industry Canada: 5251A-PC0136

Summary of Contents for 734N-WIFI

Page 1: ...INSTALLATION AND PROGRAMMING GUIDE 734N WIFI Wiegand Interface Module...

Page 2: ......

Page 3: ...nnect a Card Reader 10 Set the 734N WIFI s Address 12 TABLE OF CONTENTS Program the 734N WIFI 15 Program Start Display 15 Initialization Option 15 Initialize Confirm Option 16 Communication Menu 16 73...

Page 4: ...nd Length 24 User Code Position and Length 25 Require Site Code 25 Site Code Display 25 Enter Site Code 26 Number of User Code Digits 26 No Communication with Panel 27 Remove Keypad 28 Keypad Bus Wiri...

Page 5: ...rk access control capability to XR150 XR550 Series panels using proximity or smart card readers The 734N WIFI provides a fast safe and secure connections to your local Wi Fi network for AES encrypted...

Page 6: ...ed using a keypad connected to the 734N WIFI or from XR150 XR550 or XR150INT XR550INT Series panels KEYPAD IN AND OUT CONNECTIONS The keypad in KYPD IN connection receives and transmits data to the pa...

Page 7: ...ng Products Inc 734N WIFI Installation and Programming Guide 3 Piezo RESET PCB FEATURES DOOR RELAY TERMINAL WIEGAND INPUTS ZONES ANNUNCIATOR OUTPUTS PIEZO INDICATOR LEDS DC INPUT SMA CONNECTOR WIFI NE...

Page 8: ...IFI housing have wire entrances The back also contains multiple screw holes that allow you to mount the 734N WIFI on a single gang switch box DMP recommends mounting the 734N WIFI near the protected d...

Page 9: ...d for 10 Amps resistive at 12 24VDC When connecting multiple locks to the Form C relay the total current for all locks cannot exceed 10 Amps If the total current for all locks exceeds 10 Amps problems...

Page 10: ...LATION RELAY RED PROG J2 RED J5 RED KYPD IN J4 KYPD OUT J1 DATA XMT LED WIEGAND READ LED RELAY ON NC C NO GRN YEL RED Piezo Model 333 Supressor Normally Open Magnetic Lock Isolation Relay To Panel Key...

Page 11: ...being controlled by the relay is connected to the NO and C terminals install the suppressor on the NO and C terminals Conversely if the device is connected to the NC and C terminals install the 333 S...

Page 12: ...ion to fire devices such as heat detectors or pull stations Note You must provide a mechanical means of resetting four wire smoke detectors or other latching devices on zone 4 The panel does not drop...

Page 13: ...Inc 734N WIFI Installation and Programming Guide 9 Zone 1 Zone 2 Zone 3 Zone 4 1 2 3 4 5 6 7 8 10 11 12 13 14 9 LC AS RED WHT GRN BLK Z1 Z2 Z3 Z4 Z4 RA GND GND 1K EOL 1K EOL 1K EOL 1K EOL Figure 7 734...

Page 14: ...depending on the reader being installed Refer to the literature provided with the reader for wire coding wire distance cable type such as shielded and other specifications Card Reader LED Operation To...

Page 15: ...Installation and Programming Guide 11 Figure 8 Card Reader Wiring 1 2 3 4 5 6 7 8 10 11 12 13 14 9 LC AS RED WHT GRN BLK Z1 Z2 Z3 Z4 Z4 RA GND GND J3 ON Card Reader Red 12 24VDC White Data 1 Black GN...

Page 16: ...Bus Addresses Explained Each keypad bus address can accommodate one door output and four expansion zones A 734N WIFI with an address of 2 on the keypad bus would represent door 2 and zones 21 24 A 734...

Page 17: ...0 800 and 900 An AX Bus address can accommodate one door output and one expansion zone Because the 734N WIFI has a built in four zone expander three extra zones will be mapped to the 734N WIFI automat...

Page 18: ...13 713 716 813 813 816 913 913 916 5 51 54 517 517 520 617 617 620 717 717 720 817 817 820 917 917 920 6 61 64 521 521 524 621 621 624 721 721 724 821 821 824 921 921 924 7 71 74 525 525 528 625 625 6...

Page 19: ...You can also program the 734N WIFI from an XR150 XR550 Series panel If you choose to program the 734N WIFI from the panel all future programming should be performed through the panel The panel s progr...

Page 20: ...SURE option Selecting NO leaves communication options unchanged COMMUNICATION MENU Press any select key or area to access the programming options in the Communication menu 734N WIFI DEVICE NUMBER Ente...

Page 21: ...anel Default is 0 0 0 0 Note This IP address must match the address programmed in the panel at the Local IP Address option in Network Options The DHCP programming in the panel must be set to NO PANEL...

Page 22: ...characters for the SSID from the wireless router to identify the wireless LAN The SSID is blank by default When an SSID is entered for the first time or changed the 734N WIFI searches for the SSID ent...

Page 23: ...s The default is blank Processing the wireless key may take p to 35 seconds depending on the selected wireless security type ACCESS OPTIONS Press any select key or area to enter the programming option...

Page 24: ...es If the zone does not restore before the programmed time the 734N WIFI ends the bypass and indicates the open or short zone condition to the panel ZONE 2 BYPASS TIME Enter the number of seconds to e...

Page 25: ...a mechanical switch to zone 3 to provide REX capability to the system When zone 3 shorts the on board Form C relay activates for the programmed number of seconds see zone 3 REX Strike Time During this...

Page 26: ...r off for all operations This does not affect remote annunciator open collector RA operation The default is NO CARD OPTIONS Typically an access card contains data bits for a site code a user code and...

Page 27: ...REX TIME No user code information is sent to the panel Note When set to DMP the 734N WIFI converts 17 bits of the 26 to 45 bit data string into a 5 digit number 0 1 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 0 0...

Page 28: ...CODE POSITION AND LENGTH Enter the site code start position in the data string Then enter the number of characters the site code contains ppp is the bit position in the string that indicates the site...

Page 29: ...can only be a number between 16 40 Press the CMD key to save the entry Default is 16 REQUIRE SITE CODE Press the top row select key or area under YES to use a site code and press the CMD key to view...

Page 30: ...ss the first top row select key or area to enter a site code number Use the keypad digits to enter the three digit site code number A card with a site code greater than three digits cannot be used Use...

Page 31: ...action when communication with the panel has not occurred for five seconds Default is OFF Press any top row select key or area to change the default relay action Choose the action required when the 73...

Page 32: ...a to choose ON Relay Always On The relay is always on Press the CMD key to display the next action Press the first select key or area to choose LAST Keep Last State The relay remains in the same state...

Page 33: ...y backup Note Each panel allows a specific number of supervised keypads Add additional keypads in the unsupervised mode Maximum distance for any one bus circuit length of wire is 2 500 feet regardless...

Page 34: ...30 734N WIFI Installation and Programming Guide Digital Monitoring Products Inc CERTIFICATIONS FCC Part 15 ID CCKPC0136 Industry Canada 5251A PC0136...

Page 35: ...withstanding use in commercial business and industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructio...

Page 36: ...on distance of 20 cm is required between the antenna and all public persons Antenna Installation WARNING It is installer s responsibility to ensure that when using the authorized antennas in the Unite...

Page 37: ...ible gain and required antenna impedance Antenna types not included having a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device This device com...

Page 38: ...ximity Reader MX 5375 MaxiProx Proximity Reader PP 6005B ProxPoint Plus Proximity Reader PP 5355 ProxPro Proximity Reader with Keypad PR 5455 ProxPro II Proximity Reader TL 5395 ThinLine II Proximity...

Page 39: ...5 PRODUCT SPECIFICATIONS Primary Power 8 5 VDC to 28 5 VDC Current Draw Standby 346 mA 1 6 mA per active zone Alarm 348 mA 10 mA with Annunciator ON 2 mA per faulted zone Form C Relay 35 mA at 12 24 V...

Page 40: ......