6
734N-WIFI Installation and Programming Guide | Digital Monitoring Products, Inc.
The Form C relay can control a device that draws less than 10 Amps of current. If a
device draws more than 10 Amp of current, or the sum of all devices controlled by the
Form C relay exceeds 10 Amps, an isolation relay must be used. Refer to Figures 5 and
6 for isolation relay wiring.
3
ISOLATION RELAY
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
Model 333
Supressor
Normally Open
–
+
Magnetic Lock
–
+
Isolation Relay
To Panel
Keypad Bus
12/24VDC
Power
Supply
NC
C
NO
Figure 4: Magnetic Lock
with an Isolation Relay
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
Model 333
Supressor
Normally Open
–
+
DC Door Strike
–
+
Isolation Relay
To Panel
Keypad Bus
12/24VDC
Power
Supply
NC
C
NO
Figure 5: Door Strike with an
Isolation Relay
(optional)