24
734N-WIFI Installation and Programming Guide | Digital Monitoring Products, Inc.
CUSTOM CARD DEFINITIONS
WIEGAND CODE LENGTH
When using a custom product, enter the total number of
bits to be received in Wiegand code including parity bits.
Press any top row select key or area to enter a number
between 1-255 to equal the number of bits. Default is
26
bits.
SITE CODE POSITION AND LENGTH
Enter the site code start position in the data string. Then
enter the number of characters the site code contains.
ppp
is the bit position in the string that indicates the site
code start position. Press the second select key or area to
enter a number between 0-255. Default is
1
. Press the CMD
key to save the entry.
xx
represents the total number of site code bits used. Press
the fourth select key or area to enter a number between
1-16. Default is
8
. Press the CMD key to save the entry.
WIEGAND CODE
LENGTH:
26
SITE CODE
POS: ppp LEN: xx