USER CODE POSITION AND LENGTH
Define the user code start bit position and number of user
code bits as follows:
PPP
is the bit position in the string that indicates the user
code start position. Press the second select key or area to
enter a number between 0-255. Default is
9
. Press the CMD
key to save the entry.
XX
represents the total number of user code bits used.
Press the fourth select key or area to enter a custom
number. Custom numbers can only be a number between
16-40. Press the CMD key to save the entry. Default is
16
.
REQUIRE SITE CODE
Press the top row select key or area under
YES
to use a site
code and press the
CMD
key to view the site code entry
display. In addition to user code verification, door access is
only granted when any one site code programmed at the
SITE CODE ENTRY
option matches the site code received
in the Wiegand string.
SITE CODE DISPLAY
You can program up to eight three-digit site codes. the
site code range is 0-999. Any previously programmed
site codes display. Dashes represent blank site codes and
indicate where digits display on the keypad.
USER CODE
POS: ppp LEN: xx
REQUIRE SITE
CODE:
NO
YES
aaa bbb ccc ddd
eee fff ggg hhh