Configuring the Heat Pump Heating System
6.5
Englis
h
6.5 Modem / PC Link
It is necessary to configure the modem in the “Modem” menu.
Refer to the installation instructions of the remote diagnosis
system used regarding installation regulations. Check all
changes to the factory settings very carefully because an existing
connection could be severed.
Adjusting the interface for remote diagnostics
Setting range Display
Selects the baud rate with which data is exchanged
via the serial interface. Ensure that the same baud
rate is set on both sides of the communication
system.
19200
9600
4800
2400
1200
Always
An address can be assigned to each connection.
This value should remain set to 001 in normal
operation.
0
...
001
...
199
Always
Setting the protocol specifies which type of remote
diagnostics are used (local or modem)
Local
Remote
Modbus
GSM
Always
The remote diagnostic function can be locked by a
password
0
...
1234
...
9999
Always
This function is currently not in use
This sets which type of telephone connection is
used for remote diagnostics via modem.
Tone
Pulse
Always
Always
This sets the number of rings after which the
controller for remote diagnostics answers
0
...
1
...
9
Always
This function is currently not in use
No
Yes
Always
For diagnostic purposes (in combination with a
pCO web card), a function can be activated here
which changes the value of a variable at specific
intervals. The time basis is 1 minute. If the factor is
zero, then the function is deactivated. The variable
is output to a higher-level diagnostics device and
set from “0” to “1” for 30 seconds during the
interval.
0
...
30000
Always