EN-22
6.4
English
By activating this function, the circulation pump is
switched on constantly for a period of 24 hours.
The heat pump remains blocked during this period.
No
Yes
Circulation
Automatic program for targeted heat drying of
screed floors
Always
Sets the maximum return flow temperature to be
reached during initial heating.
25 °C
...
35 °C
...
50 °C
Always
Selecting this function will permit any request for
domestic hot water or swimming pool water during
initial heating.
No
Yes
Always
Activates the initial heating program.
No
Yes
Always
Activates the standard program for screed drying.
No
Yes
Always
Sets the duration of the individual steps during the
heating-up phase.
1
...
24
...
120
Always
Sets the maintaining time.
1
...
24
...
480
Always
Sets the duration of the individual steps during the
heating-down phase.
1
...
24
...
120
Always
Sets the temperature difference between the two
steps in the heating-up phase.
1K
...
5K
...
10K
Always
Sets the temperature difference between the two
steps in the heating-down phase.
1K
...
5K
...
10K
Always
Activates the individual program for screed drying.
No
Yes
Always
Function for the heating technician
Always
Activation of special functions
Display
Summary of Contents for WPM EconPlus
Page 4: ......
Page 44: ...DE 40 Deutsch 13 5...
Page 82: ...EN 38 13 5 English...
Page 124: ...FR 42 13 5 Fran ais...
Page 142: ...A XVIII Anhang Appendix Annexes 4...