Table A–2 (Cont.) Processor Halt Reason Code Definitions
Reason Code
(Hex)
Definition
0016
A VAXELN kernel fatal error has occurred
0017
Initializing VAXELN before starting reconfiguration
A.3 Console Halt Codes
The following example shows a console Halt code output. Table A–3 defines the
Halt Reason fields.
>>>
?03 Reset (Reason = 0013)
PC= 01E00000 PSL= 041F0300
Table A–3 Console Halt Reason Code Definitions
Reason Code
(Hex)
Definition
0000
Power-up reset
0001
Duplex zones have diverged
0002
Fatal cross-link error has occurred
0003
Fatal zone error has occurred
0004
Fatal ATM error has occurred
0005
Fatal CPU module error has occurred
0006
Fatal memory error has occurred
0007
Single bit memory error has occurred
0008
User command issued to stop a zone
0009
Unexpected machine check has occurred
000A
Software detected failure has occurred
000B
Solid NXIO error has occurred
000C
Excessive transient NCIO errors have occurred
000D
A solid IO error has occurred
000E
Excessive transient IO errors have occurred
000F
Excessive VAXELN kernel recoverable errors have occurred
0010
A VAXELN master fatal error has occurred
0011
A VAXELN job fatal error has occurred
0012
Not enough SPTEs could be allocated to boot OpenVMS
0013
Unexpected system error occurred
1
0014
Interface module failure has occurred
1
Reset reason 0013 indicates that an unexpected system error occurred. The contents of the SYSFLT,
SYSADR, and DMAADR registers will be saved in the CCA area. See Figure A–4 for the CCA offsets
of these registers. Use the register bitmaps and description in Section A.4 to determine the cause of
the error.
(continued on next page)
Miscellaneous System Information A–3