Table 4–17 (Cont.) Deconfiguration Information Block Entry Descriptions
Entry
Contents
DECONFIG_
MODULES
This field shows the Zone A modules removed from service as
a result of error handling. For example, if the source of a solid
or excessive transient error were an I/O expansion module, all
attached interface modules have been removed from service. The
following bits are defined:
00 - CPU module in slot 0 has been removed from service.
01 - I/O expansion module in slot 1 has been removed from service.
Set when the expansion module portion of the ATM module in slot 1
is removed from service. Removal of this portion of the ATM module
does not require deconfiguring the entire zone.
02 - I/O expansion module in slot 2 has been removed from service.
03 - ATM module in slot 1 has been removed from service. Set when
the entire ATM module is removed from service. The bits for all
other modules present in the zone will also be set. The entire zone
is deconfigured.
[09:04] - Not used.
10 - Interface module in slot 10 has been removed from service.
11 - Interface module in slot 11 has been removed from service.
12 - Interface module in slot 12 has been removed from service.
13 - Interface module in slot 13 has been removed from service.
14 - Interface module in slot 14 has been removed from service.
15 - Interface module in slot 15 has been removed from service.
16 - Interface module in slot 16 has been removed from service.
17 - Interface module in slot 17 has been removed from service.
[19:18] - Not used.
20 - Interface module in slot 20 has been removed from service.
21 - Interface module in slot 21 has been removed from service.
22 - Interface module in slot 22 has been removed from service.
23 - Interface module in slot 23 has been removed from service.
24 - Interface module in slot 24 has been removed from service.
25 - Interface module in slot 25 has been removed from service.
26 - Interface module in slot 26 has been removed from service.
27 - Interface module in slot 27 has been removed from service.
[31:28] - Not used.