V A X / V M S
SYSTEM ERROR REPORT
COMPILED
3-FEB-1993 09:33:44
PAGE
42.
MMBERR1_B Register Invalid
SERCSR_A REG
00000080
Loopback request
Enable query interrupt
SERCSR_B Register Invalid
SERMODE_A REG
00200912
Master
Operating System is running
'
Clock fault enable
Clock select 0 = Master, 1 = Slave
Halt source 0 = A, 1 = B
SERMODE_B Register Invalid
BIU_ADDR_A Register Invalid
BIU_ADDR_B Register Invalid
BIU_STAT_A Register Invalid
BIU_STAT_B Register Invalid
BIU_CTL_A Register Invalid
BIU_CTL_B Register Invalid
!
This block reflects the content of the four fields of the Fault Summary Block.
"
The FAULT ID, FAULT FLAG, FRU TYPE, and FRU DATA fields should
always be reviewed. They will generally provide the most immediate FRU
information.
#
The system operating mode has been changed from Duplex to Degraded
Duplex, with Zone A as the master.
$
A solid error has been identified and the FRU removed from service. However,
if the CPU has not exceeded its threshold and diagnostics pass, the CPU will
be reconfigured into the system.
%
At this point, the Zone B CPU has not been removed from service.
&
The Zone B CPU is being removed from service due to the solid error and
change in operating mode.
'
OpenVMS is running in Zone A.
4–68 Error Handling and Analysis