Table 4–15 (Cont.) Fault Summary Block Entry Descriptions
Entry
Contents
23 - Power gone end action (reserved for future use)
24 - Clock error end action
25 - Other zone halted end action (reserved for future use)
26 - Resynch abort error end action (reserved for future use)
27 - CPU-detected single-bit error end action
28 - JXD-detected single-bit error end action (reserved for future
use)
29 - CPU/MEM fault end action
2C - Zone divergence end action timeout
30 - CPU-detected DBE end action timeout
31 - JXD-detected DBE end action timeout
32 - Cable gone end action timeout (reserved for future use)
33 - Power gone end action timeout (reserved for future use)
34 - Clock error end action timeout
35 - Other zone halted end action timeout (reserved for future use)
36 - Resynch abort error end action timeout (reserved for future
use)
37 - CPU-detected SBE end action timeout
38 - JXD-detected single-bit error end action timeout (reserved for
future use)
39 - CPU/MEM fault end action timeout
3C - Zone have diverged end action timeout (reserved for future
use)
40 - VAXELN kernel fatal error
41 - VAXELN kernel recoverable error
42 - VAXELN master job fatal error
43 - VAXELN master job recoverable error
44 - VAXELN job fatal error
45 - VAXELN job recoverable error (reserved for future use)
50 - Software-detected error
60 - CPU is unsynchable
FAULT_FLAGS
The following fields are defined within FAULT_FLAGS:
00 - Transient error
01 - Solid error
02 - Error threshold exceeded
03 - Service is required
(continued on next page)