DigiOpG2 Digital Video Recorder for 4-8-16 cameras Page
37
3040-00057
10.3.
Sensor
In the preference tap, set connecting camera to the Sensor and set the sensor for External Output with various other
outputs.
Enable Sensors and Controls
Select this function to use the sensors and controls. If not selected, then
sensor indicator in the main screen will be deactivated.
Sensor Time
Select desired sensor-operating time. The default time is set as 0 to 24
hour. To use this category, turn off “Recording Schedule-> Use
Schedule.”
(Example: No.1 Sensor-> No.4,5,6,7,8
Camera-> preset 1, alarm port 1
is activated.)
Select Sensor
Select sensor for setting.
Cameras Associated with Selected Sensor
Select the camera to connect to the installed sensor. Multiple cameras
can be connected to a single sensor. Activate sensor by clicking the
desired sensor with the mouse. Then, select the camera number for the
connecting sensor.
PTZ Preset
Assign the PTZ control location in the camera connected to the sensor,
when the sensor generates, then moves automatically to the Preset
location.
Sensor Alarm Connection
When sensors detect any motion and are connected to a pre-selected
alarm, the alarm can be automatically triggered. When there is intrusion,
the sensor will be detected and the alarm output port will automatically
halt. Select sensor and camera. Then, select the alarm output port to
use. The connected alarm output port in the DigiOpG2G2 will be shown
as activating and the chosen alarm output port will change to red color.