DigiOpG2 Digital Video Recorder for 4-8-16 cameras Page
15
3040-00057
Power Cord
Connect the power cord enclosed.
Note
Before connecting the power, convert the power switch on the
power socket depending on the power, AC110V ~ 120V -
>115, AC220V~240V->230V.
Camera
Monitor
Microphone and Speaker
DigiOpG2 is compatible with PAL or NTSC camera. To get high quality
image, check the power of the whole system and the safety of the
ground construction. Also, adjust the lightening and focus or iris of the
camera properly.
Note
The camera image cannot be recorded properly when the PTZ
control signal is mixed with camera signal. In this case, connect
after separating the control signal.
EDNS-4000 supports both PC and spot monitor. Connect the analog TV
monitor to spot monitor output, and the camera images of the selected
channels will be displayed in sequence. Spot monitor output is always
displayed as full screen, and is independently controlled. For more
detailed information, refer to “Setting Customized Functions-> Select
Recording.”
1-Channel voice recording is possible in EDNS-4000, and the recorded
voice is synchronized in the channel 1. Connect the Microphone signal
for voice recording in the Microphone input jack. When voice signal is
line level, then connect to Line-in jack placed in the left of the
Microphone input jack. Also, connect with the speaker to listen to the
replay of recorded voice. Output signal is line level. Therefore, to amplify
the output signal, amp for speaker is necessary. Refer to “Viewer-
>Other Settings” for volume control.
Sensor and Alarm
Alarm I/O Terminal, which is an option, is needed to use the sensor input
and alarm output. Connect the terminal’s cable to the alarm
input/output port. Then connect each sensor and alarm wiring to the
corresponding terminal port. Sensor and alarm devices can be
connected at maximum 4 for both.
Note
Sensor and alarm are activated by relay switch. It can be
connected to either N/O (Normal Open) or N/C (Normal Close)
type and the user has to set the sensor according to each of
them. To recognize the sensor input the contact has to be
closed for at least 0.5 seconds. Please make sure that the
current of the external relay does not exceed the specifications
of the relay.
Network
Connect to network (Internet, LAN) for remote monitoring using Agent
series remote software. The IP address must be fixed and the dynamic IP
address allocated by DHCP cannot be used. Contact your dealer or
network supervisor if you need any assistance.
Printer
High quality color printer and appropriate paper type are required to
print at highest quality. Refer to “Viewer->Other Setting” for
information on the corresponding printer drive install.