MIL-3000FTX Series of FastPort Print Servers
C-11
C.8.3 Could not Read Configuration file from SERVER1
FastPort could not find the configuration file or did not have the rights to
read it.
• Configuration file is in the wrong location or misnamed
• An incorrect access right was given. Check its access rights:
a. Log in as
guest
.
b. Go to the
/login/milan
directory.
c. Type
rights
and press [Enter]. The system responds with the
current rights. Use the
Filer
command to change the rights if
necessary.
C.8.4 Trying to read file SYS:login/milan/FPXXXXXX on SERVER1
FastPort is looking for the configuration file on file server SERVER1.
C.8.5 No such object FAKEQ
There is no queue named FAKEQ. Verify it and the spelling of its queue
name.
C.8.6 Failed to login to file server SERVER1 for server FAKEPS
FastPort could not log into a nonexistent file server. The print server has
not been created in
PCONSOLE
. This error may also occur if the user has
modified the printer configuration in
PCONSOLE
. Remove any recent
configuration changes made.
C.9 ACT Error Messages
Print server not responding
• Power cycle the unit. Wait a minute and try again.
Error setting NVRAM value
• Usually due to a stale connection. Exit out of ACT and restart the utility.