![Digi IX20 User Manual Download Page 646](http://html.mh-extra.com/html/digi/ix20/ix20_user-manual_2496666646.webp)
Diagnostics
Configure options for the event and system logs
IX20 User Guide
646
d. The event categories that will be sent to the server are automatically enabled when the
server is enabled.
n
To disable informational event messages:
(config system log remote 0)> info false
(config system log remote 0)>
n
To disable status event messages:
(config system log remote 0)> status false
(config system log remote 0)>
n
To disable informational event messages:
(config system log remote 0)> error false
(config system log remote 0)>
4. Set the port number to use for the syslog server:
(config system log remote 0)> port
value
(config system log remote 0)>
where
value
is any integer between
1
and
65535
. The default is
514
.
5. Set the IP protocol to use for communication with the syslog server:
(config system log remote 0)> protocol
value
(config system log remote 0)>
where
value
is either
tcp
or
udp
. The default is
udp
.
6. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
7. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Configure options for the event and system logs
The default configuration for event and system logging is:
n
The heartbeat interval, which determines the amount of time to wait before sending a
heartbeat event if no other events have been sent, is set to 30 minutes.
n
All event categories are enabled.
To change or disable the heartbeat interval, or to disable event categories, and to perform other log
configuration:
WebUI