Central management
Collect device health data and set the sample interval
IX20 User Guide
618
(config)> cloud drm cli_local_auth true
(config)>
If set to
false
, no login prompt will be presented and the user will be logged in as
admin
. The
default is
false
.
13. (Optional) Configure the IX20 device to communicate with remote cloud services by using SMS:
a.
Enable
SMS messaging:
(config)> cloud drm sms enable true
(config)>
b. Set the phone number for Digi Remote Manager:
(config)> cloud drm sms destination
drm_phone_number
(config)>
c. (Optional) Set the service identifier:
(config)> cloud drm sms sercice_id
id
(config)>
3. (Optional) Configure the IX20 device to communicate with remote cloud services by using an
HTTP proxy server:
a.
Enable
the use of an HTTP proxy server:
(config)> cloud drm proxy enable true
(config)>
b. Set the hostname of the proxy server:
(config)> cloud drm proxy host
hostname
(config)>
c. (Optional) Set the port number on the proxy server that the device should connect to. The
default is 2138.
(config)> cloud drm proxy port
integer
(config)>
14. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
15. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Collect device health data and set the sample interval
You can enable or disable the collection of device health data to upload to Digi Remote Manager, and
configure the interval between health sample uploads. By default, device health data upload is