Monitoring
Configure NetFlow Probe
IX10 User Guide
752
8. Set the maximum number of flows to probe simultaneously:
(config)> monitoring netflow max_flows
value
(config)>
where
value
is any is any number between
0
and
2000000
. The default is
2000000
.
9. Add collectors:
a. Add a collector:
(config)> add monitoring netflow collector end
(config monitoring netflow collector 0)>
b. Set the IP address of the collector:
(config monitoring netflow collector 0)> address
ip_address
(config monitoring netflow collector 0)>
c. (Optional) Set the port used by the collector:
(config monitoring netflow collector 0)> port
port
(config monitoring netflow collector 0)>
d. (Optional) Set a label for the collector:
(config monitoring netflow collector 0)> label "This is a collector."
(config monitoring netflow collector 0)>
Repeat to add additional collectors.
10. Save the configuration and apply the change:
(config monitoring netflow collector 0)> save
Configuration saved.
>
11. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.