OPERATOR’S MANUAL
ISO
6
Version 4 Quick Start Guide
BASIC SETUP /
5
6011662 Rev B
To Unlock to Dealer Access:
1. At the Version screen,
-
Record the serial number of the ISO
6
module.
-
Press the
PASSWORD
button.
2. On the Password screen, enter the 6-digit password as
follows:
-
Enter the first digit as 2.
-
For the next five digits, enter the last five digits of the
serial number taken from the ISO
6
module found on the
label or
-
The last five digits found at the Version Information
screen (example: S/N 163210044 - use 10044).
3. Press the check button to accept password. At the Password
screen, text at screen bottom states “Dealer screens on” in
the User Level 2 (Full Access) mode.
Figure 2
Enter Password for User Level 3 Access
BASIC SETUP STEPS
The basic steps below are recommended in the listed order for
initial system setup:
1. Module Configuration (set module addresses)
2. System screen (select harness)
3. Rows (assign) Controls (define control channels)
4. Operations (define control/application configuration)
5. Materials (specify material type)
6. Row Clutch Setup (if applicable)
7. Liquid Section Setup (if applicable)
8. Geometry (implement layout)