OPERATOR’S MANUAL
ISO
6
Version 4 Quick Start Guide
ACCESSORIES
/ 41
6011662 Rev B
After a sensor has been added to the selected module, press the
created sensor row to find the
REMOVE
,
COPY
and
EDIT
softkeys. Pressing
REMOVE
deletes the sensor from the
module. Pressing
COPY
will create a new sensor with the same
properties as the highlighted sensor on the selected module as
long as the maximum number of that sensor type has not been
reached for the selected module. Pressing
EDIT
will enter the
sensor setup screen for that sensor type as seen in
sections below.
Each sensor setup screen is comprised of two pages: the first
page sets up parameters specific to that sensor type and the
second page sets up alarm parameters. The alarm parameters
have a common setup.
ACCESSORY ALARM SETUP
Page 2 of the accessory setup contains common alarm settings.
Each accessory type shares these alarm parameters:
SENSOR NAME
Pressing the Sensor Name field at the top right can change the
desired name for the sensor.
HIGH/LOW ALARM LEVEL
Enter a value for the sensor type at which the high/low warning
alarm alerts an out-of-limits state.
HIGH/LOW ALARM DELAY
Enter a value in seconds that creates a delay between the
detection of a high/low alarm condition and the resulting
alarm display.
HIGH/LOW ALARM GATING
Select where high/low alarms should display:
None:
Accessory alarms can appear regardless of the
system state.
In Work:
Accessory alarms can only appear in the
Work Screen.
Safety Input Active:
Accessory alarms can only appear the
Safety Input is active.
Implement Down In Work:
Accessory alarms can only
appear when in the Work Screen with the implement down.