CLUTCH SECTIONS
IDENTIFY SECTIONS AND OUTPUTS
MULTIPLE OUTPUT MODULE ASSIGNMENT
Output module addresses are a critical parameter used to
identify a module’s position on the implement that controls row
shutoff switches. There is a 24 clutch maximum.
IMPORTANT
If a planter uses more than one output module, modules
MUST be installed in increasing serial number order starting
on the left side and proceeding to the right so that row
assignment is configured correctly.
TO ENTER # OF OUTPUTS PER MODULE:
1. Press the
CLUTCH SECTIONS
button.
2. At the Clutch Sections screen, enter the total number
of sections.
3. Enter the number of solenoid outputs for each module.
Outputs do NOT always total the number of clutches but the
total number of controlled solenoids. The Outputs column
value is automatically sequenced for each module based on
the module address value.
4. Press the Arrow button to assign channels, rows, outputs,
and switches.
Figure 22
Clutch Output Assignment