74
DHOLLANDIA
The intended end result is a sealed heat shrink protection that completely seals and envelops:
•
the PVC basis of the incoming battery pole (3) sticking out from the rear face of the control box,
•
the bolt connection
•
and min.
½” (
10 mm) of the insulation of the battery cable (5) itself,
The heat shrink protection should protect the assembly against all water ingress and corrosion.
When mounting the cables, make sure the cables make a downward curb as they exit the control box, to allow water to drip off in a
natural way. Thus, you can easily prevent water ingress in the connections of the battery cables (1) and (5).
NOTICE
•
To ensure the reliability of the lift over many years, it is extremely important that the installer connects the battery cables to the
control boxes, heatshrinks and seals the connections with due care.
•
Insufficient torqueing of the connection bolts can cause overheating and short circuits. Improper sealing can cause water ingress,
and premature corrosion to the battery cable connection.
•
DHOLLANDIA
disclaims liability for any personal injury or property damage that results from improper or negligent installation.
❸
❸
❷
❸
❶
❺
Summary of Contents for DH-L 3300 lbs
Page 17: ...16 DHOLLANDIA LMS 55 66...
Page 28: ...27 DHOLLANDIA...
Page 49: ...48 DHOLLANDIA...
Page 52: ...51 DHOLLANDIA 11 3 1 Installation of 3 Button Wander Lead OAE002 E0784 M S...
Page 53: ...52 DHOLLANDIA 11 3 2 Installation of cabin cutoff switch OAE510 15 E0393 S 15...
Page 59: ...58 DHOLLANDIA EF0583 LM EN EF0565 EN EF0620 EN EF0580 EN CAP...
Page 60: ...59 DHOLLANDIA EF0585 US Serial Number EF0581 EN EF0563 EN EF0616 EF0562 EN...
Page 68: ...67 DHOLLANDIA...
Page 69: ...68 DHOLLANDIA...