Technical details
Deutschmann Automation GmbH & Co. KG
88
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
16 Technical details
16.1 Technical data TERM 24
Characters
TERM 24-IP54
TERM 24-IP65
Type of equipment
Display and control unit
Display and control unit
Connection to
All Deutschmann cam controls with open
communication profile
All Deutschmann cam controls with
open communication profile
Display
10 digit 7 section display; from them
5 digits for encoder position
4 digits for rotational speed
8 digits Pos. at MT
10 digit 7 section display; from them
5 digits for encoder position
4 digits for rotational speed
8 digits Pos. at MT
LCD-Display
LCD-Display 2 lines with LED-back-
ground lighting; 16 characters/line
Menu multilingual
LCD-Display 2 lines with LED-back-
ground lighting; 16 characters/line
Menu multilingual
Interface
RS 485 DICNET - max. 3 Deutschmann
terminals in one bus
RS232 (V.24)
RS 485 DICNET - max. 3 Deutschmann
Control-Units in one Network possible
RS232 (V.24)
Function-LED
Output display
Output display
Connection
Screw-plug-connector
Screw-plug-connector
Installation
Frontpanel installation
Frontpanel installation
Type of protection
IP54
IP65
Dimensions
144 x 144 x 15 mm (WxHxD)
168 x 168 x 15 mm (WxHxD)
Switchgear opening
138
+1
x 138
+1
mm
138
+1
x 138
+1
mm
Standard
Optional without extra charge
Summary of Contents for TERM 6
Page 2: ......