24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
67
Deutschmann Automation GmbH & Co. KG
Operation via TERM 24
The stored idle time is also copied when an output is copied!
14.3.7
Delete output
All cams of an output can be deleted entirely with key
if the cursor is positioned at Output.
You are then prompted to confirm whether you really do wish to delete, and you must answer
with
= YES (all data of the output is deleted) or
= NO (abort the Delete function).
Clear output?
ESC=No, ENT=Yes
14.3.8
Program-dependent idle times
Various idle times can be programmed for different programs. In order to reduce the program-
ming effort, an idle time programmed in program 0 is considered as the default idle time which
applies to all other programs unless it is explicitly programmed with a different value in this pro-
gram.
If, for example, an idle time of 10 ms is programmed in program 0 at output 1 and an idle time of
20 ms is programmed in program 1 at output 1, the idle time of program 0 applies as the default
for all programs; an idle time of 20 ms at output 1 applies only in program 1.
If an idle time has been programmed in program 0, this idle time can be
changed in other programs but cannot be deleted.
14.3.9
Change idle time compensation
For this purpose, the cursor must be positioned to the Idle time (Txxx) using the cursor keys, and
the idle time can then be changed.
Summary of Contents for TERM 6
Page 2: ......