24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
43
Deutschmann Automation GmbH & Co. KG
LOCON LTC (special version)
8.5.2
Control type 1
For this control type only one cam boss is available on the corresponding output at the controlled
input (see correspondence table).
LOCON 24 LTC is controlled within the cam if the input signal works well from 0V to 24V and
then functions from 24V to 0V.
In the synchronization cam an increase AND a decrease of the signal has to take place so
that the control functions properly.
This control type is especially needed for the short input signals or those that occur by pure
chance in the cycle (as for the ejection of a piece). It does not allow the actual long signal in the
cycle to be checked.
8.5.3
Control type 2
For this control two cam bosses are available on the corresponding output at the controlled input
(see correspondence table).