24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
75
Deutschmann Automation GmbH & Co. KG
Operation via TERM 24
14.5.1
Encoder resolution
You will see the following first item in the Configuration menu:
X00 L48 PA000
Resol. Enc: 0360
The value can be changed accordingly with the digit keys.
Please refer to chapter "Parameter description" provided with the connected cam control for a
description and value ranges for the individual parameters.
The changed value is accepted when you press key
.
14.5.2
Type of idle time compensation
You can move to the next menu item by pressing the same key again or pressing
.
You will see the following display:
X00 L32 PA000
ITC-Typ: 1
When all changes have been made and confirmed, you can quit the menu with
, whereupon
the unit automatically conducts a restart in order to accept the new configuration.
You can abort the Configuration menu any time with key
. Values already changed are
accepted.
Sub-menu items not to be changed can be skipped by pressing key
or
once. You can
move one step back at any time with
.
The unit may be configured only by qualified personnel since configura-
tion may completely change its mode of operation. Before configuration, a
general reset must be carried out in order to prevent any resultant plausi-
bility errors during the self-test.
14.5.3
DICNET No.
Pressing the same key again or pressing
moves you to the next menu item. You will see
the following display:
X00 L2 PA000
Basis-ID: 00
Summary of Contents for TERM 6