LOCON 24, 48 and 64 options
Deutschmann Automation GmbH & Co. KG
34
Instruction manual LOCON 24, 48, 64 , LTC, TERM 24 and TERM 6 V. 8.8
24.7.12
Example:
0
1
2
3
4
5
6
7
8
9
10
0
40
90
180
230
300
359
Resolution of the encoder
Volt
7.15 Option X37 - encoder monitoring
The encoder monitoring is the same as described in chapter "Encoder monitoring (option G)" on
page 30, however, deviations that /- 1 increment are detected.
7.16 Option H08 - highspeed-idle time compensation
At this option the outputs 1 - 8 are determined according to the direct ITC-calculation method. All
other outputs are treated according to the path-dependent ITC-calculation method. Further
details on the idle time compensation can be found in chapter "Function of the idle-time compen-
sation" on page 94.
7.17 Option X53 (preset value)
From the version V4.02 on the LOCON 24 features an extended scope of functions.
Function description:
In case of a configuration as incremental cam control when it comes to a "Clear" either a reset-
ting of the count to 0 (as before) or a setting to a previously entered “preset-value“ occurs.
This functionality is controlled via the signal "Pres" at pin 4 of the connector X4 (at abso-
lute encoders = encoder track 2). In case this pin is set on 0V or unwired (as it is the case in
already existing plants at present), a resetting of the count to 0 takes place. If this pin is wired
with 24V, a setting of the count to “preset-value“ takes place at every Clear.
In the state of delivery the "preset-value" equals 0. At present it can be changed either via TERM
24 (from V3.02 on), the integrated front of LOCON 24 (from V4.02 on) or WINLOC (from V1.8 on)
in the "Initialization menu". (Status 22.08.00)
7.18 Option X55 (locked outputs)
The device acts like a regular LOCON 24-V08 with the change that the access to the locked out-
puts (through the option V) is protected by a password. The password is:
0815
. The function
„Clear all“ is protected by the same password.