66
COMPRESSOR USER MANUAL
866-DTE-INFO
dentalez.com
PN: 7717-004A
SECTION V - CARE
CHECK TANK HUMIDITY
1.
On the control panel LCD display, go to the Technical
screen and press the
SENSORS >
link
(FIGURE 84)
.
2. Scroll down (if necessary) to view the tank humidity
reading
(FIGURE 85)
.
3. The tank humidity level should read between 0-20%
if running correctly. If tank humidity is above 20%,
contact Ramvac at 866-DTE-INFO.
MAINTENANCE (CONTINUED)
Runtimes
Sensors
Motors
Alerts
High Pressure Mode
Maintenance Mode
07:33:14 PM
LTE
Settings
Technical
Info
Home
FIGURE 84. PRESS SENSORS >
Technical
Motor 1 Temp
Motor 2 Temp
Motor 1 Power
Motor 2 Power
Motor 1 Current
Motor 2 Current
Tank Pressure
Tank Temp
86.2 F
88.0 F
0 Watts
0 Watts
0.0 Amps
0.0 Amps
85 PSI
72.8 F
Sensors
Technical
Ambient Temp
Ambient Humidity
Line Voltage
Regen Time
71.9 F
46.6%
243.1 V
45 sec
Tank Humidity
Pressure Dew Point
0.9%
-40.0 F
Head Duty Cycle
40.0%
FIGURE 85. VIEW TANK HUMIDITY