INSPECT DRYER
1.
Run compressor until tank pressure of at least
45 PSI/310 kPa shows on the Home screen of the
control panel LCD display
(FIGURE 74)
.
2. On the Technical screen, press and enable
MAINTENANCE MODE (FIGURE 75)
.
NOTE:
Turning ON maintenance mode disables
remote switching and puts the system in STANDBY
mode.
3. Carefully open the tank petcock
(FIGURE 76)
.
4. If no water drains from the tank when the valve is
opened, the dryer is working; proceed to step 6.
5. If water drains from the tank when the valve is opened,
the dryer is not working, contact Ramvac at 866-DTE-
INFO.
MAINTENANCE (CONTINUED)
SECTION V - CARE
TANK
PETCOCK
FIGURE 76. OPEN TANK PETCOCK
FIGURE 74. RUN COMPRESSOR TO 45 PSI/310 KPA