55
(2) Bluetooth
communications parameters
Items Parameters
Defaults
Refer
to:
Non-acknowledge mode
Communications protocol
ACK/NAK mode
Section 9.1 (1)
None
Header
STX
ETX
CR
LF
Terminator
CR LF
Section 9.2 (1)
As a master
As a slave
Configure the scanner as master or slave
No slave/master configuration change
Section 2.2
Bluetooth
address
Local name
Connection target of scanner as master
Communications adapter
(BA10-RKU)
Section 2.2
Specification of connection target's address
(only when local name is specified)
Connection target's address
None
Section 2.2
2 minutes
4 minutes
10 minutes
Timeout period for slave to wait for a
connection request
30 minutes
Section 9.1 (2)
5 to 640 minutes
60 min.
Timeout period for automatic disconnection
of the Bluetooth
wireless link
Disable automatic disconnection
Section 9.1 (3)
Start operation
Bluetooth
interface
End operation
Section 2.1
(See Note 1.)
(Note 1) The factory default is "End operation."
: Changeable only with the QR-coded parameter menu.
: Changeable only with the configuration software.