66
[4.5] Setting the communications environments
After the BHT is initialized, the interface port and communications parameters are set as listed in the
default table below. Do not access them unless necessary.
Interface port
Optical (IrDA interface port)
Communications protocol
YMODEM
Communications parameters
for the IrDA interface port
Defaults
TRANSMIT SPEED
115200 bps
SERIAL No.:
ON (Adds serial numbers to data
blocks.)
H. PARITY:
ON (Adds a horizontal parity.)
LINKUP TIME:
30 seconds
PROTOCOL (Protocol options)
FIELD SPACE: Ignore (Trim)
Listed below are the default communications parameters for the direct-connect interface.
Communications parameters
for the direct-connect interface port
Defaults
TRANSMIT SPEED
115200 bps
PARITY BIT (Vertical parity)
None
DATA BIT (Character length)
8 bits
STOP BIT (Stop bit length)
1 bit
SERIAL No.:
ON (Adds serial numbers to data
blocks.)
H. PARITY:
ON (Adds a horizontal parity.)
LINKUP TIME:
30 seconds
PROTOCOL (Protocol options)
FIELD SPACE: Ignore (Trim)